A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: Network is unreachable

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

An electrochemical method for simultaneous detection and identification of Escherichia coli, Staphylococcus aureus and Salmonella choleraesuis using a glucose oxidase-peroxidase composite biosensor. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Quantification of bacterial pollution by amperometric detection at 0.0 V of glucose consumption at a graphite-Teflon-glucose oxidase-peroxidase-ferrocene composite biosensor under flow injection conditions is reported. Using Escherichia coli as the model bacterium, the composition of the growing medium was optimized. A constant glucose concentration of 4.0 x 10(-4) M was added to the culture medium. The relative response to glucose, expressed as the ratio between the amperometric signal and the signal at incubation time t = 0 multiplied by 100, as a function of E. coli concentration, showed a typical behaviour. Limits of detection of 6.5 x 10(2) or 6.5 cfu mL(-1) were achieved after 3 or 7 h of incubation, respectively, with no pre-concentration step. The detection of bacteria did not affect the lifetime of the biosensor. The feasibility of the detection of Staphylococcus aureus and Salmonella choleraesuis throughout the glucose consumption measurement at the composite biosensor is also demonstrated. The capability of bacterial identification by evaluation of bacterial growth in the culture medium containing the antibiotics polymyxin B, vancomycin, erythromycin, bacitracin, chloramphenicol, tetracycline and ciprofloxacin, was investigated. Each micro-organism tested exhibited a different antibiotic susceptibility profile, thus suggesting the possibility of bacteria differentiation. A rapid methodology for screening of bacteria is proposed.

Download full-text PDF

Source
http://dx.doi.org/10.1039/b618159gDOI Listing

Publication Analysis

Top Keywords

composite biosensor
12
escherichia coli
8
staphylococcus aureus
8
aureus salmonella
8
salmonella choleraesuis
8
choleraesuis glucose
8
glucose consumption
8
culture medium
8
detection
5
glucose
5

Similar Publications