Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Upper extremity musculoskeletal modeling is becoming increasingly sophisticated, creating a growing need for subject-specific muscle size parameters. One method for determining subject-specific muscle volume is magnetic resonance imaging (MRI). The purpose of this study was to determine the validity of MRI-derived muscle volumes in the human forearm across a variety of muscle sizes and shapes. Seventeen cadaveric forearms were scanned using a fast-spoiled gradient echo pulse sequence with high isotropic spatial resolution (1mm(3) voxels) on a 3T MR system. Pronator teres (PT), extensor carpi radialis brevis (ECRB), extensor pollicis longus (EPL), flexor carpi ulnaris (FCU), and brachioradialis (BR) muscles were manually segmented allowing volume to be calculated. Forearms were then dissected, muscles isolated, and muscle masses obtained, which allowed computation of muscle volume. Intraclass correlation coefficients (ICC(2,1)) and absolute volume differences were used to compare measurement methods. There was excellent agreement between the anatomical and MRI-derived muscle volumes (ICC = 0.97, relative error = 12.8%) when all 43 muscles were considered together. When individual muscles were considered, there was excellent agreement between measurement methods for PT (ICC = 0.97, relative error = 8.4%), ECRB (ICC = 0.93, relative error = 7.7%), and FCU (ICC = 0.91, relative error = 9.8%), and fair agreement for EPL (ICC = 0.68, relative error = 21.6%) and BR (ICC = 0.93, relative error = 17.2%). Thus, while MRI-based measurements of muscle volume produce relatively small errors in some muscles, muscles with high surface area-to-volume ratios may predispose them to segmentation error, and, therefore, the accuracy of these measurements may be unacceptable.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2083633PMC
http://dx.doi.org/10.1016/j.jbiomech.2007.04.005DOI Listing

Publication Analysis

Top Keywords

relative error
24
muscle volume
12
muscle
9
magnetic resonance
8
resonance imaging
8
imaging mri
8
subject-specific muscle
8
mri-derived muscle
8
muscle volumes
8
measurement methods
8

Similar Publications

A rapid and specific liquid chromatography-tandem mass spectrometry method with a wide linear range was developed and validated for the simultaneous quantification of Vitamin K1 (VK1) trans- and cis- isomers in human plasma. Bovine serum albumin solution (15%) served as a surrogate matrix for preparing the calibrators to establish the quantitative curves. After liquid-liquid extraction, VK1 trans- and cis- isomers in plasma samples were separated on a ChromCore C30 column (15 cm × 4.

View Article and Find Full Text PDF

The fruit fly Anastrepha fraterculus (Wiedemann) (Diptera: Tephritidae) is one of the main pests in apple orchards. Artificial neural networks (ANNs) are tools with good ability to predict phenomena such as the seasonal dynamics of pest populations. Thus, the objective of this work was to determine a prediction model for the seasonal dynamics of A.

View Article and Find Full Text PDF

Developing Clinically Interpretable Neuroimaging Biotypes in Psychiatry.

Biol Psychiatry

September 2025

Department of Psychiatry and Behavioral Sciences, Stanford University School of Medicine, Stanford, CA, 94305, USA; Sierra-Pacific Mental Illness Research, Education, and Clinical Center (MIRECC), Veterans Affairs Palo Alto Health Care System, Palo Alto, CA, 94304, USA. Electronic address: leawillia

Despite available treatments, major depressive disorder (MDD) remains one of the leading causes of disability across medical conditions. The current symptom-based diagnostic system groups patients with highly heterogeneous presentations, with no biomarkers to guide treatment-akin to diagnosing heart disease solely by chest pain, without imaging to reveal the underlying pathology. Lacking biological guidance, clinicians rely on trial-and-error prescribing.

View Article and Find Full Text PDF

Agricultural sources, landfills, and hazardous waste disposal sites (HWDS) are major hotspots for the spread of groundwater antibiotic resistance genes (ARGs) and human bacterial pathogens (HBPs). However, there is a lack of systematic understanding regarding the environmental behavior of groundwater ARGs, the pathogenic risks of HBPs, and the relative contribution mechanisms of different sources, presenting critical scientific challenges for developing targeted groundwater pollution control strategies. To address this, this study collected 26 groundwater metagenomic samples to characterize the composition, influencing factors, and health risks of ARGs and HBPs near key ARG reservoirs, and constructed a source-tracking indicator system.

View Article and Find Full Text PDF

Slimmer Geminals For Accurate F12 Electronic Structure Models.

J Chem Theory Comput

September 2025

Department of Chemistry, Virginia Tech, Blacksburg, Virginia 24060, United States.

The Slater-type F12 geminal length scales originally tuned for the second-order Mo̷ller-Plesset F12 method are too large for higher-order F12 methods formulated using the SP (diagonal fixed-coefficient spin-adapted) F12 ansatz. The new geminal parameters reported herein reduce the basis set incompleteness errors (BSIEs) of absolute coupled-cluster singles and doubles F12 correlation energies by a significant─and increase with the cardinal number of the basis─margin. The effect of geminal reoptimization is especially pronounced for the cc-pVZ-F12 basis sets (specifically designed for use with F12 methods) relative to their conventional aug-cc-pVZ counterparts.

View Article and Find Full Text PDF