Article Abstract

Unlabelled: The aim of this study was to elucidate the clinical usefulness of scatter correction with an artificial neural network (ANN) in 99mTc and 123I dual-isotope SPECT.

Methods: Two algorithms for ANN scatter correction were tested: ANN-10 and ANN-3 employing 10 and 3 energy windows for data acquisition, respectively. Three patients underwent myocardial or brain SPECT with one of the following combinations of radiopharmaceuticals administered: 99mTc-tetrofosmin and 123I-metaiodobenzylguanidine (MIBG), 99mTc-methoxyisobutylisonitrile (MIBI) and 123I-beta-methyl-paraiodophenyl-pentadecanoic acid (BMIPP), or 99mTc-ethyl-cistainate dimmer (ECD) and 123I-iomazenil. The patients were also referred for single-isotope imaging incorporating conventional triple-energy window (TEW) scatter correction. Crosstalk- and scatter-corrected 99mTc- and 123I-SPECT images in dual-isotope acquisition with ANN were compared with those in single-isotope acquisition.

Results: The ANN method well separated 123I and 99mTc primary photons. Although ANN-10 yielded images of poor quality, ANN-3 offered comparable image quality with the single-isotope scan without significant increase of acquisition time.

Conclusion: The proposed method is clinically useful because it provides various combinations of information without anatomical misregistration with one acquisition.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF03033996DOI Listing

Publication Analysis

Top Keywords

scatter correction
16
artificial neural
8
neural network
8
99mtc 123i
8
123i dual-isotope
8
myocardial brain
8
scatter
4
correction based
4
based artificial
4
network 99mtc
4

Similar Publications

In ultrasound imaging, propagation of an acoustic wavefront through heterogeneous media causes phase aberrations that degrade the coherence of the reflected wavefront, leading to reduced image resolution and contrast. Adaptive imaging techniques attempt to correct this phase aberration and restore coherence, leading to improved focusing of the image. We propose an autofocusing paradigm for aberration correction in ultrasound imaging by fitting an acoustic velocity field to pressure measurements, via optimization of the common midpoint phase error (CMPE), using a straight-ray wave propagation model for beamforming in diffusely scattering media.

View Article and Find Full Text PDF

Abtract: PURPOSE: To evaluate the correlation between corneal backscatter and visual function in patients with Fuchs endothelial corneal dystrophy (FECD).

Study Design: Prospective case series.

Methods: This study included 53 eyes from 38 patients with FECD.

View Article and Find Full Text PDF

Purpose: To evaluate visual and refractive outcomes, visual quality, patient satisfaction, and spectacle independence 3 months after phacoemulsification with bilateral non-diffractive enhanced depth of focus (EDOF) lens implantation.

Methods: This study included 68 eyes of 34 consecutive patients, with 51.5% undergoing refractive lens exchange and 48.

View Article and Find Full Text PDF

Previous studies have suggested potential associations between some dietary factors and oral mucosal lesions (OMLs), however, existing research could be biased due to limited sample size and unaccounted confounding factors. This study aimed to explore the causal relationships between 13 common dietary factors and 3 OMLs using 2-sample Mendelian randomization (MR) analysis. Data for the MR analysis were extracted from publicly available genome-wide association study statistics.

View Article and Find Full Text PDF

Purpose: The combination of multi-layer flat panel detector (FPDT) X-ray imaging and physics-based material decomposition algorithms allows for the removal of anatomical structures. However, the reliability of these algorithms may be compromised by unaccounted materials or scattered radiation.

Approach: We investigated the two-material decomposition performance of a multi-layer FPDT in the context of 2D chest radiography without and with a 13:1 anti-scatter grid employed.

View Article and Find Full Text PDF