A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Low-energy gamma-emitting stents inhibit intimal hyperplasia with minimal "edge effects" in a pig coronary artery model. | LitMetric

Low-energy gamma-emitting stents inhibit intimal hyperplasia with minimal "edge effects" in a pig coronary artery model.

Cardiovasc Revasc Med

Roy and Ann Foss Interventional Cardiology Research Program, Terrence Donnelly Heart Center, St. Michael's Hospital, University of Toronto, Toronto, Ontario, Canada.

Published: April 2007


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: The objective of this study was to determine the effects of different doses of gamma-emitting radioactive stents on intimal hyperplasia in a porcine coronary stent model at 28 days.

Methods: Sixty-four bare stents and those coated with palladium-103 [activities of 0 (control), 0.5, 1.0, 2.0, and 4.0 mCi] were implanted in the coronary arteries of 32 pigs. Stented segments were evaluated by histomorphometry at 28 days.

Results: There was significantly more intima in the 0.5- and 1-mCi stents than in controls (4.27+/-0.52 and 4.71+/-1.13 vs. 1.71+/-0.61 mm(2); P<.0001). Neointimal formation in 2-mCi stents was similar to that in controls, while that in 4-mCi stents was reduced compared to that in controls (2.34+/-1.61 and 0.82+/-0.25 vs. 1.71+/-0.61 mm(2); P=NS and P<.05, respectively). Stent margin neointimal response was representative of that within the stent body, with nonsignficant modest increases in intimal area at adjacent nonstented segments in radioactive stent groups. There was a dose-dependent increase in inflammation scores. Radioactive stents had lower intimal smooth muscle and higher fibrin scores. There was an increase in adventitial fibrosis in 1- and 2-mCi stents versus controls (1.26+/-0.99, and 2.25+/-1.27 vs. 0.21+/-0.31; P<.001).

Conclusion: Dose-response inhibition of in-stent hyperplasia with minimal "edge effects" occurs with low-energy gamma-emitting stents. An increased inflammatory response at higher doses in palladium-103 stents indicates that later follow-up studies are necessary.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.carrev.2006.09.006DOI Listing

Publication Analysis

Top Keywords

intimal hyperplasia
8
low-energy gamma-emitting
4
stents
4
gamma-emitting stents
4
stents inhibit
4
inhibit intimal
4
hyperplasia minimal
4
minimal "edge
4
"edge effects"
4
effects" pig
4

Similar Publications