Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The performances of three multivariate analysis methods--partial least squares (PLS) regression, secured principal component regression (sPCR) and modified secured principal component regression (msPCR)--are compared and tested for the determination of human serum albumin (HSA), gamma-globulin, and glucose in phosphate buffer solutions and blood glucose quantification by near-infrared (NIR) spectroscopy. Results from the application of PLS, sPCR and msPCR are presented, showing that the three methods can determine the concentrations of HSA, gamma-globulin and glucose in phosphate buffer solutions almost equally well provided that the prediction samples contain the same spectral information as the calibration samples. On the other hand, when some potential spectral features appear in new measurements, sPCR and msPCR outperform PLS significantly. The reason for this is that such spectral features are not included during calibration, which leads to a degradation in PLS prediction performance, while sPCR and msPCR can improve their predictions for the concentrations of the analytes by removing the uncalibrated features from the original spectra. This point is demonstrated by successfully applying sPCR and msPCR to in vivo blood glucose measurements. This work therefore shows that sPCR and msPCR may provide possible alternatives to PLS in cases where some uncalibrated spectral features are present in measurements used for concentration prediction.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-006-0977-1DOI Listing

Publication Analysis

Top Keywords

spcr mspcr
20
secured principal
16
principal component
16
component regression
16
gamma-globulin glucose
12
buffer solutions
12
blood glucose
12
spectral features
12
regression secured
8
modified secured
8

Similar Publications

The performances of three multivariate analysis methods--partial least squares (PLS) regression, secured principal component regression (sPCR) and modified secured principal component regression (msPCR)--are compared and tested for the determination of human serum albumin (HSA), gamma-globulin, and glucose in phosphate buffer solutions and blood glucose quantification by near-infrared (NIR) spectroscopy. Results from the application of PLS, sPCR and msPCR are presented, showing that the three methods can determine the concentrations of HSA, gamma-globulin and glucose in phosphate buffer solutions almost equally well provided that the prediction samples contain the same spectral information as the calibration samples. On the other hand, when some potential spectral features appear in new measurements, sPCR and msPCR outperform PLS significantly.

View Article and Find Full Text PDF