98%
921
2 minutes
20
The differential scattering cross section in electron energy loss near edge spectroscopy (ELNES) generally depends on the orientation of the Q wave vector transferred from the incident electron to an atomic core electron. In the case where the excited atom belongs to a threefold, fourfold or sixfold main rotation axis, the dipole cross section depends on the angle of Q with respect to this axis. In this paper, we restrict to this situation called dichroism. Furthermore, if we take into account the relativistic effects due to the high incident electron velocity, this dipole cross section also depends on the angle of Q with respect to the electron beam axis. It is due to these dependences that the shape of measured electron energy loss spectra varies with the electron beam incidence, the collector aperture, the incident beam convergence and the incident electron energy. The existence of a particular beam incidence angle for which the scattering cross section becomes independent of collection and beam convergence semi-angles is clearly underscored. Conversely, it is shown that EELS spectra do not depend on the beam incidence angle for a set of particular values of collection and convergence semi-angles. Particularly, in the case of a parallel incident beam, there is a collection semi-angle (often called magic angle) for which the cross section becomes independent of the beam orientation. This magic angle depends on the incident beam kinetic energy. If the incident electron velocity V is small compared with the light velocity c, this magic angle is about 3.975theta(E) (theta(E) is the scattering angle). It decreases to 0 when V approaches c. These results are illustrated in the case of the K boron edge in the boron nitride.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ultramic.2005.12.003 | DOI Listing |
J Synchrotron Radiat
November 2025
Advanced Photon Source, Argonne National Laboratory, Lemont, IL 60439, USA.
Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on.
View Article and Find Full Text PDFAnn Surg Oncol
September 2025
Breast Service, Department of Surgery, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
Background: Although several trials have demonstrated the oncologic safety of partial-breast irradiation (PBI) compared with whole-breast irradiation (WBI), data on patient-reported outcomes are mixed. Here we compare breast satisfaction and chest well-being using the BREAST-Q questionnaire among patients undergoing PBI versus WBI.
Patients And Methods: We identified patients undergoing lumpectomy and radiation, and analyzed their BREAST-Q scores preoperatively and postoperatively at 6 months, 1 year, 2 years, and 3 years.
Adv Radiat Oncol
October 2025
Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Radiation Oncology and Radiotherapy, Augustenburger Platz 1, 13353 Berlin, Germany.
Purpose: To evaluate the impact of an optimized online adaptive radiation therapy workflow on physician involvement.
Methods And Materials: Data from a prospective phase 2 trial involving 34 prostate cancer patients treated with cone beam computed tomography (CBCT)-based online adaptive radiation therapy (62 Gy in 20 fractions) were analyzed. Manual interventions were required for 2 steps in the workflow: radiation therapy technologist review and adjustment of automatically segmented organs, guiding target segmentation, so-called "influencer," while physicians reviewed and refined the targets.
Radiat Res
September 2025
Division of Genetics and Epidemiology, Institute of Cancer Research, London, United Kingdom.
Contralateral breast (CB) cancer is the most common subsequent cancer among breast cancer survivors, and radiotherapy has been linked to CB cancer risk. The purpose of this work was to evaluate doses to subregions of the contralateral breast from historical breast cancer treatments carried out in the United States between 1990 and 2012. We extracted treatment data from radiation therapy summaries for 2,442 radiotherapy patients during that period.
View Article and Find Full Text PDFAerosp Med Hum Perform
September 2025
Introduction: Pilots have an increased incidence of cutaneous melanoma compared to the general population; occupational exposure to ultraviolet (UV) radiation is one of several potential risk factors. Cockpit windshields effectively block UVB (280-315 nm) but further analysis is needed for UVA (315-400 nm). The objective of this observational study was to assess transmission of UVA through cockpit windshields and to measure doses of UVA at pilots' skin under daytime flying conditions.
View Article and Find Full Text PDF