Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Right ventricular (RV) dysfunction is a predictor of poor outcome in patients with heart disease. Conventional imaging modalities fail to assess RV volumes accurately. We sought to assess the accuracy and reproducibility of routine breath-hold gradient echo magnetic resonance imaging (MRI)-derived RV mass, volumes and function. We assessed: (1) The accuracy of in vivo MRI-derived RV mass in comparison to the RV weight in 9 minipigs. (2) Intra- and inter-observer reproducibility of RV mass, end-diastolic (EDV) and end-systolic (ESV) volumes and ejection fraction (EF) in 15 normal volunteers and 10 patients with heart disease. (3) Inter-study reproducibility of the former parameters in 25 coronary artery disease patients. (4) The correlation between right and left ventricular stroke volumes in the total population. Strong statistically significant correlations were found between: (1) MRI-derived RV mass and RV weight (r = 0.98, bias = 2.5 g), (2) Intra-observer measurements of RV mass (r = 0.96, bias = 0.5 g), EDV (r = 0.99, bias = -1.5 ml), ESV (r = 0.98, bias = 0.1 ml) and EF (r = 0.92, bias = -1.4%), (3) Inter-observer measurements of RV mass (r = 0.95, bias = 1.1 g), EDV (r = 0.98, bias = -1.1 ml), ESV (r = 0.98, bias = 1.2 ml) and EF (r = 0.87, bias = -1.9%), (4) Inter-study measurements of RV mass (r = 0.91, bias = -0.1 g), EDV (r = 0.96, bias = 3.8 ml), ESV (r = 0.98, bias = 0.3 ml) and EF (r = 0.90, bias = 0.9%), (5) MRI-derived right and left ventricular stroke volumes (r = 0.87). The assessment of the RV mass, volumes and function by routine breath-hold gradient echo MRI is accurate and highly reproducible. The correlation between left and RV MRI-derived stroke volumes indicates excellent coherence of simultaneous bi-ventricular volume measurements.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10554-004-1097-7DOI Listing

Publication Analysis

Top Keywords

098 bias
20
bias
13
routine breath-hold
12
breath-hold gradient
12
gradient echo
12
mass volumes
12
volumes function
12
mri-derived mass
12
stroke volumes
12
measurements mass
12

Similar Publications

Purpose: This systematic review aims to examine the literature of artificial intelligence (AI) algorithms in the diagnosis of hepatocellular carcinoma (HCC) among focal liver lesions compared to radiologists on multiphase CT images, focusing on performance metrics that include sensitivity and specificity as a minimum.

Methods: We searched Embase, PubMed and Web of Science for studies published from January 2018 to May 2024. Eligible studies evaluated AI algorithms for diagnosing HCC using multiphase CT, with radiologist interpretation as a comparator.

View Article and Find Full Text PDF

Background: Artificial intelligence (AI) has demonstrated transformative potential in the health care field; yet, its clinical adoption faces challenges such as inaccuracy, bias, and data privacy concerns. As the primary operators of AI systems, physicians and nurses play a pivotal role in integrating AI into clinical workflows. Their acceptance and use of AI are essential for bridging the gap between technological innovation and practical implementation.

View Article and Find Full Text PDF

Background: Acute hospitalisation is a recognised risk factor for adverse outcomes in older adults, including hospital-associated disability. Post-discharge exercise interventions might mitigate physical and cognitive decline, although the few meta-analyses performed previously present limitations. This systematic review and meta-analysis aimed to evaluate the effect of post-discharge exercise interventions on health-related outcomes in older adults.

View Article and Find Full Text PDF

We explore a new class of chipscale torsion pendula formed by Si_{3}N_{4} nanoribbon suspensions. Owing to their unique heirarchy of gravitational, tensile, and elastic stiffness, the devices exhibit damping rates of ∼10  μHz and parametric gravity sensitivities near that of an ideal pendulum. The suspension nonlinearity can also be used to cancel the pendulum nonlinearity, paving the way toward fully isochronous, high Q pendulum gravimeters.

View Article and Find Full Text PDF

Introduction: Termination of resuscitation (TOR) rules in out of hospital cardiac arrest (OHCA) varies across different healthcare settings and populations. This study aimed to externally validate ten TOR rules for predicting death before hospital admission among OHCA patients.

Methods: A retrospective prognostic accuracy study analyzed 379 non-trauma OHCA patients (≥18 years) in Bangkok who were either treated by the emergency medical services (EMS) of Ramathibodi Hospital or transported to Ramathibodi's emergency department by another EMS provider (January 2010 - March 2023).

View Article and Find Full Text PDF