Control of low-concentration pollutants from a semiconductor process vent stream using a wet-scrubbing technique is a challenging task to meet Taiwan environmental emission standards. An efficient wet-scrubber is designed on a pilot scale and tested to control low concentration acid and base waste-gas emission. The scrubber system consisted of two columns, i.e., a fine spray column [cutoff diameter (based on volume), Dv(50) = 15.63 microm; Sauter mean diameter (SMD) = 7.62 microm], which is especially efficient for NH3 removal as the pH of the spraying liquid is approximately 7 followed by a packed column with a scrubbing liquid pH approximately 9.0 mainly for acids removal. It is observed that use of the surfactants in low concentration about 10(-4) M and 10(-7) M in the spray liquid and in the scrubbing liquid, respectively, remarkably enhances the removal efficiency of the system. A traditional packed column (without the spray column and the surfactant) showed that the removal efficiencies of NH3, HF, and HCl for the inlet concentration range 0.2 to 3 ppm were (n = 5) 22.6+/-3.4%, 43.4+/-5.5%, and 40.4+/-7.4%, respectively. The overall efficiencies of the proposed system (the spray column and the packed column) in the presence of the surfactant in the spray liquid and in the scrubbing liquid forthese three species were found to increase significantly (n = 5) from 60.3+/-3.6 to 82.8+/-6.8%, 59.1+/-2.7 to 83.4+/-4.2%, and 56.2+/-7.3 to 81.0+/-6.7%, respectively. In this work, development of charge on the gas-liquid interface due to the surfactants has been measured and discussed. It is concluded that the presence of charge on the gas-liquid interface is the responsible factor for enhancement of the removal efficiency (mass-transfer in liquid phase). The effects of the type of surfactants, their chain length, concentration in liquid, etc. on the removal efficiency are discussed. Since the pilot tests were performed under the operating conditions similar to most of the wet-scrubbers operated in semiconductors manufacturing facilities for inorganic pollutants, this study can be applied to modify the existing wet-scrubbers to enhance the removal efficiencies, especially for low-concentration pollutants.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/es035241w | DOI Listing |
Eur J Mass Spectrom (Chichester)
June 2025
Analys Lab Private Limited, Hyderabad, India.
A high-performance liquid chromatography-tandem mass spectrometry method has been developed for the quantification of ertugliflozin in human plasma, employing ertugliflozin D5 as the internal standard. Methyl tertiary butyl ether-based liquid-liquid extraction technique was employed, followed by chromatographic separation on Kromasil-C (100 × 4.6 mm, 5 µm) column using a mixture of methanol and 10 mM ammonium formate buffer (80:20, v/v) as the mobile phase at a flow rate of 1 mL/min.
View Article and Find Full Text PDFMethodsX
December 2025
Department of Chemistry, School of Science, RK University, Rajkot, India.
This study reports a sensitive and selective method developed and validated for the detection of process-related genotoxic impurity (PGI) formed in situ during the synthesis of topiramate API. The method utilizes benzyl amine as a derivatizing agent to enhance sensitivity. of impurity.
View Article and Find Full Text PDFJ Pharm Biomed Anal
November 2025
Nanjing Research and Development Center, Jiangsu Hengrui Pharmaceuticals Co., Ltd, Nanjing 210009, PR China; Jiangsu Yuanchuang Medicine Research and Development Co., Ltd, Nanjing 210009, PR China.
Hetrombopag (Hengqu®) is an oral nonpeptide thrombopoietin receptor agonist for the treatment of thrombocytopenia and aplastic anemia. Research on the pharmacokinetic behavior is very important, but accurate quantification of metal-sensitive hetrombopag in biological specimens is a challenging analytical problem. In view of the presence of trace metals from a variety of sources, such as chromatographic system, containers, and the mass spectrometry spray needle, which can contribute to poor peak shape, tailing, and diminished recovery of compound.
View Article and Find Full Text PDFAnal Chem
July 2025
Department of Chemistry and Chemical Biology, Indiana University Indianapolis, Indianapolis, Indiana 46202, United States.
The continued rise in overdoses, driven by fentanyl and novel psychoactive substances (NPS), underscores the need for improved methods for drug screening. Traditional analytical techniques involving chromatography can be time-consuming and require sample preparation. Paper spray mass spectrometry (PS-MS) can rapidly detect analytes from complex matrices.
View Article and Find Full Text PDFJ Chromatogr A
August 2025
Zhejiang Academy of Science and Technology for Inspection and Quarantine, Hangzhou, Zhejiang 311215, China.
A rapid screening method was developed to simultaneous determine 12 fluorescent whitening agents (FWAs) in paper and plastic food packaging materials for infants by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The sample was ultrasonically extracted by the mixed solvent of tetrahydrofuran-40 % acetonitrile aqueous solution. Separation was performed on Eclipse XDB-C18 chromatographic column (150 mm×4.