Article Abstract

An experimental tracking optical coherence tomography (OCT) system has been clinically tested. The prototype instrument uses a secondary sensing beam and steering mirrors to compensate for eye motion with a closed-loop bandwidth of 1 kHz and tracking accuracy, to within less than the OCT beam diameter. The retinal tracker improved image registration accuracy to <1 transverse pixel (<60 microm). Composite OCT images averaged over multiple scans and visits show a sharp fine structure limited only by transverse pixel size. As the resolution of clinical OCT systems improves, the capability to reproducibly map complex structures in the living eye at high resolution will lead to improved understanding of disease processes and improved sensitivity and specificity of diagnostic procedures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1937334PMC
http://dx.doi.org/10.1364/ol.29.002139DOI Listing

Publication Analysis

Top Keywords

tracking optical
8
optical coherence
8
coherence tomography
8
tomography experimental
4
experimental tracking
4
tomography oct
4
oct system
4
system clinically
4
clinically tested
4
tested prototype
4

Similar Publications

Background: Lung ischemia-reperfusion injury (LIRI) is a pathological condition characterized by aggravated oxidative-inflammatory tissue damage that occurs upon blood flow restoration after ischemia. LIRI can lead to severe complications, including primary graft dysfunction in lung transplants and multi-organ failure. However, current treatments remain limited.

View Article and Find Full Text PDF

Background: Sulfur dioxide (SO) is recognized as a major atmospheric pollutant and its excessive emissions can pose a great threat to the environment, flora and fauna, and human health. Long-term exposure to excessive SO can cause chronic poisoning, leading to neurological disorders and cardiovascular diseases. However, there are two sides to everything.

View Article and Find Full Text PDF

At the beginning of the twenty-first century, the primary view of infant visual attention development focused on a transition across the first postnatal year from being stimulus-driven to goal-driven, reflecting a broader shift from subcortical to cortical control. This perspective was supported by decades of infant looking-time studies. However, our understanding of infant attention has significantly evolved over the past 25 years, shaped by both theoretical advancements and new technological and methodological tools.

View Article and Find Full Text PDF

Left Ventricular Motion Analysis Framework for the MATRIX-VT Study.

Int J Comput Assist Radiol Surg

September 2025

Department of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Ratzeburger Allee 160, Lübeck, 23652, Germany.

Purpose: Ultrasound (US) is commonly used to assess left ventricular motion for examination of heart function. In stereotactic arrhythmia radioablation (STAR) therapy, managing cardiorespiratory motion during radiation delivery requires representation of motion information in computed tomography (CT) coordinates. Similar to conventional US-guided navigation during surgical procedures, 3D US can provide real-time motion data of the radiation target that could be transferred to CT coordinates and then be accounted for by the radiation system.

View Article and Find Full Text PDF