A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Intraductal ultrasonography and endoscopic retrograde cholangiography in diagnosis of extrahepatic bile duct stones: a comparative study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Intraductal ultrasonography (IDUS) is highly accurate in detection of extrahepatic bile duct stones. This study was to compare the accuracy of IDUS and endoscopic retrograde cholangiography (ERC) in the diagnosis of extrahepatic bile duct stones.

Methods: Thirty patients suspected of extrahepatic bile duct stones on B ultrasonography, CT, or MRI were enrolled for study. ERC was performed using a Fujinon duodenoscope (ED-410XT, ED-410Xu), then IDUS was done by inserting a Fujinon microprobe (PL2220-15) through the endoscopic biopsy channel to detect the extrahepatic bile duct. Finally stones in the extrahepatic bile duct were detected and extracted by endoscopic sphincterotomy (EST).

Results: Among the 30 patients, 26 were diagnosed as having cholelithiasis accurately through ERC. In one patient the stone detected by ERC was really floccule. Misdiagnosis happened in 2 patients with extrahepatic bile duct stones. So the overall accuracy and sensitivity of ERC in the diagnosis of extrahepatic bile duct stones were 86.7% (26/30) and 92.9% (26/28) respectively. In contrast, IDUS showed the results of diagnosis were in consistent with those of EST stone extraction. Its accuracy and sensitivity in the diagnosis of extrahepatic bile duct stones were 100% (30/30) and 100% (28/28) respectively.

Conclusion: IDUS which is superior to ERC in diagnosing extrahepatic bile duct stones can avoid the visual error of ERC.

Download full-text PDF

Source

Publication Analysis

Top Keywords

extrahepatic bile
40
bile duct
40
duct stones
28
diagnosis extrahepatic
16
extrahepatic
10
bile
10
duct
10
intraductal ultrasonography
8
endoscopic retrograde
8
retrograde cholangiography
8

Similar Publications