98%
921
2 minutes
20
Cyclophosphamide is a known human carcinogen. In July 1999, in a report at a conference on cytotoxic drugs in Sweden, it was indicated that cyclophosphamide (CP) was not effectively controlled by high efficiency particulate air (HEPA) filters.((1)) This then raised a concern that the existing air monitoring methods, which utilize polytetrafluoroethylene (a.k.a. PTFE, or Teflon) or glass fiber filters for evaluation of antineoplastics such as CP in air may also be ineffective for collection and quantification of such agents. It was decided that further evaluation of the existing filter method for monitoring antineoplastics in air be conducted. This evaluation determined that the filter method of monitoring was minimally effective for some antineoplastic agents, and that an alternate method of monitoring should be sought. The method subsequently developed utilizes a solid sorbent tube, Anasorb 708, a methacrylic acid polymer. Evaluation of this sorbent tube for adsorption and desorption properties found it had a greater than 90 percent recovery for both CP and ifosfamide. Other agents evaluated included 5-fluorouracil, doxorubicin, and paclitaxel. All three agents were able to be detected and measured by use of Anasorb 708 solid sorbent tube. Validation of the method was then conducted with air pulled through the tubes via attachment to an air manifold system at air flows ranging from 1.5 to approximately 4.0 liters per minute for up to 24 hours. This evaluation did validate the Anasorb 708 tube as an effective media for collection of airborne concentrations of CP from less than 1 microgram up to approximately 2 mg (2000 microgram) per tube. This corresponds to a concentration range of approximately 0.7 microgram/m(3) (0.0007 mg/m(3)) to 0.7 mg/m(3) in a 5.76 m(3) volume of air. This method can provide accurate information on airborne concentrations of CP for purposes of conducting risk assessments or evaluation of risk management methods.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/10473220301435 | DOI Listing |
Anal Sci
September 2025
Key Laboratory of Poyang Lake Environment and Resource Utilization, Ministry of Education, School of Resources and Environment, Nanchang University, Nanchang, 330031, People's Republic of China.
The accurate detection of trace perfluoroalkyl acids (PFAAs) in drinking water remains challenging due to nonspecific adsorption losses during pretreatment. This study systematically evaluated the adsorption behaviors of 11 PFAAs across five filtration membranes and four solid-phase extraction (SPE) sorbents to establish an optimized analytical protocol. Results demonstrated that glass fiber (GL) filters minimized PFAAs retention (94.
View Article and Find Full Text PDFAnal Chim Acta
November 2025
Department of Analytical Chemistry, Faculty of Chemistry, Alzahra University, Vanak, Tehran, Iran; Analytical and Bioanalytical Research Centre, Alzahra University, Vanak, Tehran, Iran. Electronic address:
Background: Determination of the estradiol hormone in urine is crucial for evaluating congenital adrenal hyperplasia, certain hormone-producing ovarian tumors, polycystic ovary syndrome, liver disease, pregnancy, and infertility. On the other hand, steroid hormones can have destructive effects on the environment, animals, and the endocrine system of humans. Consequently, accurately measuring this hormone's concentration in trace amounts is essential for environmental safety and human health.
View Article and Find Full Text PDFACS Cent Sci
August 2025
Department of Chemistry and Biomolecular Sciences, University of Ottawa, 10 Marie Curie Private, Ottawa, Ontario K1N 6N5, Canada.
Metal-organic framework (MOF) materials have attracted significant attention as solid sorbents for low energy CO capture with adsorption-based gas separation processes. In this work, an integrated screening workflow combining a series of atomistic and process simulations was applied to identify promising MOFs for a 4-step pressure-vacuum swing adsorption (P/VSA) process at three different CO flue gas compositions (6%, 15% and 35%). Starting from 55,818 unique experimentally characterized MOFs, ∼19k porous MOFs were investigated via atomistic grand canonical Monte Carlo (GCMC) simulations and machine learning model-based process optimizations to accelerate the screening of a large candidate database.
View Article and Find Full Text PDFChemSusChem
September 2025
Laboratoire de Chimie, ENS de Lyon and CNRS, Lyon, 69364, France.
The challenge of CO separation and management in biogas upgrading processes is addressed, which remains a critical bottleneck when considering biomethane as a competitive and sustainable alternative to natural gas. Ionic liquids offer a promising alternative to existing sorbents due to their negligible volatility and their tunable properties. Herein, a multifunctional phosphonium triazolate ionic liquid capable of reacting reversibly with CO without loss of fluidity through both cation and anion is presented.
View Article and Find Full Text PDFSci Rep
September 2025
Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
An in-situ CO₂-assisted dispersive micro solid phase extraction was developed using a covalent organic framework synthesized from melamine and barbituric acid as a sorbent for the extraction of Cd(II) and Zn(II) ions from honey samples. The structural and morphological characteristics of the sorbent were evaluated using scanning electron microscopy, X-ray diffraction, and Fourier transform infrared spectrometry. The CO₂ generated by reacting tartaric acid and sodium hydrogen carbonate enabled rapid dispersion of the sorbent within the sample solution, ensuring optimal contact with the target ions.
View Article and Find Full Text PDF