Article Abstract

As part of an effort to quantify device-dependent differences in forearm bone density, 101 women, aged 20-80 years (approximately 16 women in each age decade), were scanned on six forearm bone densitometers: the Aloka DCS-600EX, the Hologic QDR-4500A, the Lunar PIXI, the Norland pDEXA, the Osteometer DTX-200, and the Pronosco X-posure System. Regression statistics are reported for all similar regions of interest (ROIs). However, comparisons were confounded because of large differences in the ROI size and placement. The number of ROIs reported for a single scan by each device varied from 1 to 12. The correlation coefficients ranged from 0.7 < r < 0.97, with the highest correlation coefficients and lowest SEs for comparisons between the most similar ROIs. Standardized units of bone mineral density are derived for distal (sdBMD), mid-(smBMD), and proximal (spBMD) ROTs that allow for comparable mean bone densities to be derived for patient populations. Five phantoms were scanned and characterized on five of the devices and the precision and mean values were reported. These phantom values will aid in the in vitro cross-calibration between manufacturers to recreate the presented in vivo relationships. Care should be exercised when using these equations for cross-calibrating patient databases or pooling clinical data from different devices because the least significant differences detectable from measurements taken on two different machines can be increased substantially.

Download full-text PDF

Source
http://dx.doi.org/10.1359/jbmr.2002.17.4.734DOI Listing

Publication Analysis

Top Keywords

forearm bone
12
correlation coefficients
8
bone
5
universal standardization
4
standardization forearm
4
bone densitometry
4
densitometry effort
4
effort quantify
4
quantify device-dependent
4
device-dependent differences
4

Similar Publications

Introduction: Fractures are a common occurrence in childhood, with approximately one-third of boys and girls sustaining at least one fracture before the age of 17. Both-bone forearm fractures, particularly those involving the radius and ulna, are more common in the non-dominant hand and in boys and usually involve the distal portions of both bones. If not properly treated, these injuries can have a significant impact on limb function.

View Article and Find Full Text PDF

Objective: The treatment of severe post-traumatic elbow stiffness is extremely complex. Complete open release of the elbow joint and reconstruction of stiffness-related injuries are considered crucial; however, these procedures may lead to elbow instability, particularly chronic instability due to underlying conditions. This retrospective study aimed to assess the outcomes of using an internal joint stabilizer (IJS) to ensure post-release stability in these complex cases.

View Article and Find Full Text PDF

[Management of forearm shaft fractures : Challenges and solution approaches].

Unfallchirurgie (Heidelb)

September 2025

Klinik für Orthopädie und Unfallchirurgie, Klinikum Nürnberg, Paracelsus Medizinische Privatuniversität, Breslauer Straße 201, 90471, Nürnberg, Deutschland.

Forearm shaft fractures are the most common fractures of the upper extremity in young adults. By definition, these fractures are diaphyseal fractures; however, due to the complex functional unity formed by the forearm shaft during motion both bone forearm fractures are treated as intra-articular fractures [1, 3]. This is why the gold standard of treatment in adults is osteosynthesis.

View Article and Find Full Text PDF

Radius-Adjustable Ring Ultrasound Transducer Array for Real-Time 3D Imaging of Large Volume Targets.

Ultrasound Med Biol

September 2025

School of Electronic Science and Engineering, Nanjing University, Nanjing, Jiangsu, China. Electronic address:

Objective: Three-dimensional (3D) ultrasound imaging overcomes the limitations of 2D ultrasound images by providing comprehensive spatial information. However, challenges remain when imaging larger body parts like legs and arms using traditional linear transducer arrays. The main difficulties include limited scanning range and angle, bone interference that affects penetration depth, and registration difficulties caused by squeezing targets.

View Article and Find Full Text PDF

Physical activity appears to be a strong determinant of the building of peak bone mass and the degree of bone mineralization in young adult males. This study aimed to describe the impact of volleyball (V), throwing athletes (TA), climbing (CL), snowboarding participation (SN), fracture history, hand grip strength (HGS), and body composition on forearm bone mineral density (BMD) in males. BMD, bone mass content (BMC), and T-score of the distal (dis) and proximal (prox) parts of the forearm were measured by the DXA technique.

View Article and Find Full Text PDF