Publications by authors named "Patrick D Wolf"

Real-time 3-D intracardiac echocardiography (ICE) can enable faster imaging of surfaces orthogonal to the transducer, such as the pulmonary vein (PV) antra and cardiac valve annuli. However, the requirement for a 2-D grid of individually wired elements makes a traditional matrix array challenging to implement within an intravenous catheter. Helicoid array transducers are linear array transducers twisted about their long axis, allowing imaging of different elevation slices using sub-apertures.

View Article and Find Full Text PDF

Objectives: Intraventricular pressure (IVP) is one of the most important measurements for evaluating cardiac function, but this measurement is not currently easily assessable in the clinic. The primary reason for this is the absence of a noninvasive technique for measuring IVP. In this study, we investigate the relationship between IVP and dynamic myocardial stiffness measured by shear wave elasticity imaging (SWEI) and assess the feasibility of measuring IVP using SWEI.

View Article and Find Full Text PDF

Shear wave elasticity imaging (SWEI) is a novel ultrasound elastography technique for assessing tissue stiffness. In this study, we investigate the potential of SWEI for providing diastolic functional assessment. In 11 isolated rabbit hearts, pressure-volume (PV) measurements were recorded simultaneously with SWEI recordings from the left ventricle free wall before and after induction of global ischemia.

View Article and Find Full Text PDF

Background: Myocardial contractility, a significant determinant of cardiac function, is valuable for diagnosis and evaluation of treatment in cardiovascular disorders including heart failure. Shear wave elasticity imaging (SWEI) is a newly developed ultrasound-based elastographic technique that can directly assess the stiffness of cardiac tissue. The aim of this study was to verify the ability of this technique to quantify contractility changes in the myocardium.

View Article and Find Full Text PDF

In the past decade, there has been an increased interest in characterizing cardiac tissue mechanics utilizing newly developed ultrasound-based elastography techniques. These methods excite the tissue mechanically and track the response. Two frequently used methods, acoustic radiation force impulse (ARFI) and shear-wave elasticity imaging (SWEI), have been considered qualitative and quantitative techniques providing relative and absolute measures of tissue stiffness, respectively.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates how elastography imaging techniques, specifically shear wave elasticity imaging (SWEI) and acoustic radiation force impulse (ARFI), can assess tissue stiffness changes during and after radiofrequency ablation (RFA) in dogs.* -
  • Measurements were taken at RFA sites in six canines, revealing an immediate increase in tissue stiffness during ablation, with the stiffness area stabilizing two minutes post-ablation, while adjacent areas saw a slight increase over 15 minutes.* -
  • Overall, the results indicate that these ultrasound techniques can reliably monitor and assess tissue stiffness shortly and up to 30 minutes after RFA, highlighting their potential for consistent lesion evaluation.*
View Article and Find Full Text PDF

The possibility of measuring cardiac function noninvasively has generated wide interest in elastography imaging techniques. Shear Wave Elasticity Imaging (SWEI) is an ultrasound-based elastography technique used to measure stiffness of tissues. While this technique has been studied extensively in static homogenous tissues such as liver, breast or prostate, there is still a significant need to study its capabilities to measure cardiac stiffness and function.

View Article and Find Full Text PDF

Diastolic heart failure (DHF) is a major source of cardiac related morbidity and mortality in the world today. A major contributor to, or indicator of DHF is a change in cardiac compliance. Currently, there is no accepted clinical method to evaluate the compliance of cardiac tissue in diastolic dysfunction.

View Article and Find Full Text PDF

Background: Visual confirmation of radiofrequency ablation (RFA) lesions during clinical cardiac ablation procedures could improve procedure efficacy, safety, and efficiency. It was previously shown that acoustic radiation force impulse (ARFI) imaging can identify RFA lesions in vitro and in vivo in an animal model. This is the "first-in-human" feasibility demonstration of intracardiac ARFI imaging of RFA lesions in patients undergoing catheter ablation for atrial flutter (AFL) or atrial fibrillation (AF).

View Article and Find Full Text PDF

We developed new forward-viewing matrix transducers consisting of double ring arrays of 118 total PZT elements integrated into catheters used to deploy medical interventional devices. Our goal is 3D ultrasound guidance of medical device implantation to reduce x-ray fluoroscopy exposure. The double ring arrays were fabricated on inner and outer custom polyimide flexible circuits with inter-element spacing of 0.

View Article and Find Full Text PDF

The most common mechanical measure of the heart integrates ventricular strain between end-diastole and end-systole in order to provide a measure of contraction. Here an approach is described for estimating a correlate to local passive mechanical properties. Passive strain is measured by estimating ventricular strain during atrial systole.

View Article and Find Full Text PDF
Article Synopsis
  • This study investigates the use of acoustic radiation force impulse (ARFI) imaging to visualize changes in tissue stiffness after radiofrequency ablation (RFA) in canine subjects.
  • The main goals were to measure the displacements caused by ARFI in both ablated and unablated heart tissue and to evaluate the contrast and quality of ARFI images compared to standard echo images.
  • Results showed that ARFI images had a higher accuracy in identifying lesion sites and produced better contrast and contrast-to-noise ratios than conventional imaging methods.
View Article and Find Full Text PDF

Acoustic radiation force impulse (ARFI) imaging has been shown to be capable of imaging local myocardial stiffness changes throughout the cardiac cycle. Expanding on these results, the authors present experiments using cardiac ARFI imaging to visualize and quantify the propagation of mechanical stiffness during ventricular systole. In vivo ARFI images of the left ventricular free wall of two exposed canine hearts were acquired.

View Article and Find Full Text PDF

Background: Arrhythmia recurrence after cardiac radiofrequency ablation (RFA) for atrial fibrillation has been linked to conduction through discontinuous lesion lines. Intraprocedural visualization and corrective ablation of lesion line discontinuities could decrease postprocedure atrial fibrillation recurrence. Intracardiac acoustic radiation force impulse (ARFI) imaging is a new imaging technique that visualizes RFA lesions by mapping the relative elasticity contrast between compliant-unablated and stiff RFA-treated myocardium.

View Article and Find Full Text PDF

Acoustic radiation force (ARF)-based methods have been demonstrated to be a viable tool for noninvasively estimating tissue elastic properties, and shear wave velocimetry has been used to measure quantitatively the stiffening and relaxation of myocardial tissue in open-chest experiments. Dynamic stiffness metrics may prove to be indicators for certain cardiac diseases, but a clinically viable means of remotely generating and tracking transverse wave propagation in myocardium is needed. Intracardiac echocardiography (ICE) catheter-tip transducers are demonstrated here as a viable tool for making this measurement.

View Article and Find Full Text PDF

Vagus nerve stimulation (VNS) is effective for treating epilepsy and depression, and has emerging indications for anxiety and heart failure. However, stimulation-evoked side effects remain a challenge for long-term compliance. We investigated the feasibility of reducing VNS side effects by using a temporally-modified stimulation pattern.

View Article and Find Full Text PDF

In this study, we investigated the feasibility of using 3.5-Fr intravascular ultrasound (IVUS) catheters for minimally-invasive, image-guided hyperthermia treatment of tumors in the brain. Feasibility was demonstrated by: (1) retro-fitting a commercial 3.

View Article and Find Full Text PDF

Vagus nerve stimulation (VNS) is an approved treatment for epilepsy and depression, and it is currently under investigation for applications in Alzheimer's disease, anxiety, heart failure, and obesity. However, the mechanism(s) by which VNS has its effects are not clear, and the stimulation parameters for obtaining therapeutic outcomes appear highly variable. The purpose of this study was to quantify the excitation properties of the right cervical vagus nerve in adult dogs anesthetized with propofol and fentanyl.

View Article and Find Full Text PDF

Introduction: Lesion placement and transmurality are critical factors in the success of cardiac transcatheter radiofrequency ablation (RFA) treatments for supraventricular arrhythmias. This study investigated the capabilities of catheter transducer based acoustic radiation force impulse (ARFI) ultrasound imaging for quantifying ablation lesion dimensions.

Methods And Results: RFA lesions were created in vitro in porcine ventricular myocardium and imaged with an intracardiac ultrasound catheter transducer capable of acquiring spatially registered B-mode and ARFI images.

View Article and Find Full Text PDF

Shear wave elasticity imaging (SWEI) was employed to track acoustic radiation force impulse (ARFI)-induced shear waves in the mid-myocardium of the left ventricular free wall (LVFW) of a beating canine heart. Shear waves were generated and tracked with a linear ultrasound transducer that was placed directly on the exposed epicardium. Acquisition was ECG-gated and coincided with the mid-diastolic portion of the cardiac cycle.

View Article and Find Full Text PDF

Acoustic radiation force impulse (ARFI) imaging has been demonstrated to be capable of visualizing changes in local myocardial stiffness through a normal cardiac cycle. As a beating heart involves rapidly-moving tissue with cyclically-varying myocardial stiffness, it is desirable to form images with high frame rates and minimize susceptibility to motion artifacts. Three novel ARFI imaging methods, pre-excitation displacement estimation, parallel-transmit excitation and parallel-transmit tracking, were implemented.

View Article and Find Full Text PDF

In this study, we investigated the feasibility of an intracranial catheter transducer with dual-mode capability of real-time 3D (RT3D) imaging and ultrasound hyperthermia, for application in the visualization and treatment of tumors in the brain. Feasibility is demonstrated in two ways: first by using a 50-element linear array transducer (17 mm x 3.1 mm aperture) operating at 4.

View Article and Find Full Text PDF

A fully implantable neural data acquisition system is a key component of a clinically viable brain-machine interface. This type of system must communicate with the outside world and obtain power without the use of wires that cross through the skin. We present a 96-channel fully implantable neural data acquisition system.

View Article and Find Full Text PDF

Thresholding is an often-used method of spike detection for implantable neural signal processors due to its computational simplicity. A means for automatically selecting the threshold is desirable, especially for high channel count data acquisition systems. Estimating the noise level and setting the threshold to a multiple of this level is a computationally simple means of automatically selecting a threshold.

View Article and Find Full Text PDF