Internal carotid artery (ICA) stenoses are a major source of stroke. In addition to traditional cardiovascular risk factors, hemodynamic parameters such as wall shear stress (WSS) are recognized as critical contributors to the progression and rupture of ICA plaques. This study evaluates the ability of 4D flow MRI to predict the velocity and WSS fields in three models of carotid bifurcations representing stenosis ratios of 0% (healthy), 40% (mildly stenosed), and 80% (severely stenosed) in the ICA.
View Article and Find Full Text PDFSevere aortic valve stenosis can lead to heart failure and aortic valve replacement (AVR) is the primary treatment. However, increasing prevalence of aortic stenosis cases reveal limitations in current replacement options, necessitating improved prosthetic aortic valves. We investigate flow disturbances downstream of severe aortic stenosis and two bioprosthetic aortic valve (BioAV) designs using advanced energy-based analyses.
View Article and Find Full Text PDFAortic valve replacement has become an increasing concern due to the rising prevalence of aortic stenosis in an ageing population. Existing replacement options have limitations, necessitating the development of improved prosthetic aortic valves. In this study, flow characteristics during systole in a stenotic aortic valve case are compared with those downstream of two newly designed surgical bioprosthetic aortic valves (BioAVs).
View Article and Find Full Text PDFThe etiology of transcatheter heart valve thrombosis (THVT) and the relevance of the aortic root geometry on the occurrence of THVT are largely unknown. The first aim of this pilot study is to identify differences in aortic root geometry between THVT patients and patients without THVT after transcatheter aortic valve implantation (TAVI). Second, we aim to investigate how the observed difference in aortic diameters affects the aortic flow using idealized computational geometric models.
View Article and Find Full Text PDFCalcific degeneration is the most frequent type of heart valve failure, with rising incidence due to the ageing population. The gold standard treatment to date is valve replacement. Unfortunately, calcification oftentimes re-occurs in bioprosthetic substitutes, with the governing processes remaining poorly understood.
View Article and Find Full Text PDFPurpose: First, to investigate the agreement between velocity, velocity gradient, and Reynolds stress obtained from four-dimensional flow magnetic resonance (4D flow MRI) measurements and direct numerical simulation (DNS). Second, to propose and optimize based on DNS, 2 alternative methods for the accurate estimation of wall shear stress (WSS) when the resolution of the flow measurements is limited. Thirdly, to validate the 2 methods based on 4D flow MRI data.
View Article and Find Full Text PDFObjective: The flow downstream from aortic stenoses is characterised by the onset of shear-induced turbulence that leads to irreversible pressure losses. These extra losses represent an increased resistance that impacts cardiac efficiency. A novel approach is suggested in this study to accurately evaluate the pressure gradient profile along the aorta centreline using modelling of haemodynamic stress at scales that are smaller than the typical resolution achieved in experiments.
View Article and Find Full Text PDFCardiac implants may have a strong influence on the hemodynamics of the circulatory system. In this study, we aimed at investigating the impact of transcatheter aortic valve implantation (TAVI) devices on blood flow patterns that develop in the ascending aorta under physiological flow conditions in vitro. For this purpose, a noninvasive optical measurement tool, three-dimensional particle tracking velocimetry (3D-PTV), was used in a realistic compliant silicone aortic model.
View Article and Find Full Text PDFWe investigate the flow past two transcatheter aortic valves (TAVs) and one severely calcified valve in an anatomically realistic aorta geometry to evaluate the ability of the TAVs to establish a healthier aortic flow compared to a diseased case. Velocity measurements of pulsatile flow are carried out using the 3D-particle tracking velocimetry technique. We present a novel approach based on the Smagorinsky model to assess the important subvoxel-scale (here smaller than 750 [Formula: see text]m) shear stress contribution that is usually unavailable in experiments.