Background: PET/CT image quality is directly influenced by the F-18-FDG injected activity. The higher the injected activity, the less noise in the reconstructed images but the more radioactive staff exposition. A new FDA cleared software has been introduced to obtain clinical PET images, acquired at 25% of the count statistics considering US practices.
View Article and Find Full Text PDFObjective: To assess FDG cerebral PET in patients suffering from cognitive impairment linked to Long COVID. The COVID pandemic has affected dozens of millions of people around the world and has resulted in the deaths of more than 3 million people. Following the acute forms, it has been reported sometimes long forms of COVID, with involvements of several organs including the brain.
View Article and Find Full Text PDFMany patients who have suffered from acute COVID infections have long-lasting symptoms affecting several organs including the brain. This long COVID status can include "brain fog" and cognitive deficits that can disturb activities of daily living and can delay complete recovery. Here, we report two cases of neurological long COVID with abnormal FDG PET findings marked by hypometabolic regions of the cingulate cortex.
View Article and Find Full Text PDFBackground And Purpose: The in vivo diagnosis of cerebral amyloid angiopathy (CAA) is currently based on the Boston criteria, which largely rely on hemorrhagic features on brain magnetic resonance imaging. Adding to these criteria F-fluoro-deoxy-D-glucose (FDG) positron emission tomography, a widely available imaging modality, might improve their accuracy. Here we tested the hypothesis that FDG uptake is reduced in posterior cortical areas, particularly the primary occipital cortex, which pathologically bear the brunt of vascular Aβ deposition.
View Article and Find Full Text PDFBackground: Cerebral amyloid angiopathy (CAA) is a frequent cause of both intracerebral hemorrhage (ICH) and cognitive impairment in the elderly. Diagnosis relies on the Boston criteria, which use magnetic resonance imaging markers including ≥2 exclusively lobar cerebral microbleeds (lCMBs). Although amyloid positron emission tomography (PET) may provide molecular diagnosis, its specificity relative to Alzheimer's disease (AD) is limited due to the prevalence of positive amyloid PET in cognitively normal elderly.
View Article and Find Full Text PDFWe describe the results of F-FDG PET/CT of 3 patients referred to our institution during the single day of Monday, March 23, 2020, for an initial assessment of cancer extension or for the therapeutic evaluation of chemotherapy of neoplastic pathology, with no obvious infectious or respiratory symptoms at the time of examination. A retrospective review of the recent clinical history of patients in association with the typical pulmonary images on CT scan suggested the diagnosis of COVID-19. The characteristic aspects of COVID-19 infection should be recognized on F-FDG PET/CT, even if patients are asymptomatic or minimally symptomatic.
View Article and Find Full Text PDFEur J Nucl Med Mol Imaging
September 2020
Purpose: The aim of this series of cases is to show the aspects of ventilation/perfusion single-photon emission computed tomography combined with computed tomography (V/Q SPECT/CT) in patients hospitalized for COVID-19 pneumonia, with the worsening of respiratory symptoms raising the suspicion of a pulmonary embolism. Patients did not benefit from CT angiography for various reasons: a contraindication, unavailability of the CT angiography, or a low clinical probability for pulmonary embolism.
Methods: We retrospectively describe the results of the V/Q SPECT/CT of five patients hospitalized for COVID-19 pneumonia in the nuclear medicine departments of the Centre Cardiologique du Nord and of the Delafontaine hospital in Saint-Denis (Ile-de-France, France) between April 2, 2020, and April 10, 2020.
Eur J Nucl Med Mol Imaging
February 2020
Purpose: Brain positron emission tomography using 18F-fluorodeoxyglucose (18FDG-PET) provides a metabolic assessment of brain function that is useful for differential diagnosis among several neurodegenerative diseases manifested by cognitive impairment (CI). The purpose of the study is to describe the pattern of 18FDG-PET abnormalities in patients with CI related to alcohol use disorder.
Methods: Patients admitted to the addiction medicine department of a university hospital in Paris between January 2017 and October 2018 with a confirmed diagnosis of alcohol-related cognitive impairment (ARCI) or Wernicke encephalopathy (WE) were included.
Background: We studied the impact of technetium-99m (Tc) in the thallium-201 (Tl) energy window (70 keV) to determine if CZT cardiac cameras allow us to perform simultaneous dual-isotope acquisition for myocardial perfusion imaging.
Methods: We included 117 consecutive patients. We injected 0.
Fusariosis is an opportunistic infection, caused by a filamentous fungus, found on plants and in soil. The treatment of disseminated pattern, seen in immunocompromised patients with severe neutropenia, is difficult because of antifungal therapy resistance. A 12-year-old girl, who was diagnosed with B-cell acute lymphoblastic leukemia, developed multiple widespread skin papules and subcutaneous nodules, at day 20 of consolidation therapy.
View Article and Find Full Text PDFUnlabelled: The aim of this study was to assess the prognostic value of normal ultra-low-dose exercise MPI with a CZT camera.
Methods: 1901 consecutive patients without known CAD referred for exercise MPI with 1.8 MBq/kg (0.
Clin Nucl Med
November 2015
A 26-year-old man with chronic terminal renal insufficiency under dialysis was referred in our institution for a checkup before kidney transplantation to ensure the absence of malignant neoplasm. The patient had a biological secondary hyperparathyroidism with highly elevated serum parathormon, and treatment with parathyroid surgery was planned before the kidney transplant. Whole-body FDG PET/CT showed no apparent malignant neoplasm, but increased metabolism of the 4 parathyroid gland and the other pitfalls of advanced secondary hyperparathyroidism on chronic renal insufficiency: pseudotumoral calcification in soft tissues, diffuse hypermetabolic bone dystrophy, and osteolytic lesion of pelvic and peripheral skeleton corresponding to brown tumors.
View Article and Find Full Text PDFClin Nucl Med
August 2012
We report our first experience of brain DaTSCAN SPECT imaging using cadmium-zinc-telluride gamma camera (CZT-GC) in 2 cases: a 64-year-old patient suffering from essential tremor and a 73-year-old patient presenting with atypical bilateral extrapyramidal syndrome. In both cases, 2 different acquisitions were performed and compared, using a double-head Anger-GC, followed immediately by a second acquisition on CZT-GC. There were no significant visual differences between images generated by different GC.
View Article and Find Full Text PDFNucl Med Commun
May 2012
Objectives: Thallium-201 is efficient for myocardial perfusion imaging, but leads to relatively high radiation exposure in patients. The purpose of this study was to compare the efficiency of low-dose thallium-201 imaging with cadmium-zinc-telluride (CZT) cameras with regular-dose thallium-201 imaging with conventional cameras.
Methods: We prospectively studied 137 consecutive patients referred for stress myocardial perfusion imaging who had previously had a myocardial single-photon emission computed tomography with thallium-201.
A 70-year-old man underwent a thallium-201 brain SPECT in the work-up and characterization of a frontotemporal mass. SPECT images were performed on cadmium zinc telluride system during only 5 minutes and after the injection of only 2 mCi. Images demonstrated high thallium uptake in frontotemporal areas considered as a potential malignant tumor.
View Article and Find Full Text PDFPurpose Of The Report: Cadmium zinc telluride (CZT) solid-state detectors have been recently introduced in myocardial perfusion imaging. However, they had not been yet validated with thallium-201. This study compares the clinical performances of the CZT ultrafast camera GE DNM 530c with a conventional SPECT camera (CC) using thallium-201.
View Article and Find Full Text PDF