Publications by authors named "John D Hummel"

Background: Despite over a century of clinical electrocardiographic studies showing that women exhibit a faster resting heart rate (HR), the mechanisms underlying sex differences in HR remain unresolved. Moreover, inappropriate sinus tachycardia primarily affects women, whereas men are at a higher risk for conduction block and atrial fibrillation. We hypothesized that the sexual dimorphism of genes responsible for sinoatrial node (SAN) pacemaking and signaling pathways may contribute to the sex differences in HR and susceptibility to arrhythmias.

View Article and Find Full Text PDF

Although pulmonary vein isolation (PVI) has become the cornerstone ablation procedure for atrial fibrillation (AF), the optimal ablation procedure for persistent and long-standing persistent AF remains elusive. Targeting spatio-temporal electrogram dispersion in a tailored procedure has been suggested as a potentially beneficial alternative to a conventional PVI-only procedure. In this multicenter, randomized, controlled, double-blind, superiority trial, patients with drug-refractory persistent AF were randomly assigned to a tailored ablation procedure targeting areas of spatio-temporal dispersion, as detected by an artificial intelligence (AI) algorithm, in addition to PVI (tailored arm, n = 187, 23% women) or to a conventional PVI-only procedure (anatomical arm, n = 183, 19% women).

View Article and Find Full Text PDF

Background: The SPHERE Per-AF trial demonstrated noninferiority for a primary composite effectiveness endpoint in patients with persistent atrial fibrillation (AF) treated with a 9-mm, lattice-tip, pulsed field (PF)/radiofrequency (RF) system (74%) vs conventional contact force-sensing RF (65%). Although operators were highly experienced with the control, the vast majority was new to the investigational system.

Objective: The aim of this study was to assess the learning curve using this novel system.

View Article and Find Full Text PDF

Background: There is a paucity of data regarding the optimal timing of left atrial appendage closure (LAAC) and whether scheduling delays increase the risk for adverse outcomes.

Objectives: This study sought to assess the incidence and predictors of adverse events among patients awaiting LAAC.

Methods: This single-center retrospective study assessed all patients who underwent LAAC from January 2017 to March 2020.

View Article and Find Full Text PDF

Background: Peridevice leak (PDL) after left atrial appendage closure (LAAC) portends adverse outcomes.

Objective: The purpose of this study was to assess the incidence, predictors, clinical implications, and temporal evolution of PDL after LAAC.

Methods: This single-center retrospective study included all patients who underwent LAAC with Watchman FLX and had no PDL detected at the time of implantation.

View Article and Find Full Text PDF
Article Synopsis
  • Catheter ablation for atrial fibrillation (AF) faces challenges due to difficulties in producing durable lesions, leading to suboptimal outcomes.
  • A study involving 420 patients compared a new large-tip catheter using both pulsed field and radiofrequency energies to traditional radiofrequency methods, finding that 73.8% of patients in the new group met effectiveness criteria, compared to 65.8% in the control group.
  • The new approach also resulted in fewer major complications and shorter procedural times, suggesting that the dual-energy catheter could be a safer and more effective treatment for persistent AF, though more extensive studies are needed to confirm these findings in larger populations.
View Article and Find Full Text PDF

Background: Injury to the esophagus has been reported in a high percentage of patients undergoing ablation of atrial fibrillation (AF).

Objectives: This study assessed the incidence of esophageal injury in patients undergoing ablation of AF with and without an esophageal deviating device.

Methods: This prospective, randomized, multicenter, double-blinded, controlled Food and Drug Administration investigational device exemption trial compared the incidence of ablation-related esophageal lesions, as assessed by endoscopy, in patients undergoing AF ablation assigned to a control group (luminal esophageal temperature [LET] monitoring alone) compared with patients randomized to a deviation group (esophagus deviation device + LET).

View Article and Find Full Text PDF

Introduction: Among patients with non-valvular atrial fibrillation (AF) and percutaneous left atrial appendage closure (LAAC) undergoing direct current cardioversion (DCCV), the need for and use of LAA imaging and oral anticoagulation (OAC) is unclear.

Objective: The purpose of this study is to evaluate the real-world use of transesophageal echocardiography (TEE) or cardiac computed tomography angiography (CCTA) before DCCV and use of OAC pre- and post-DCCV in patients with AF status post percutaneous LAAC.

Methods: This retrospective single center study included all patients who underwent DCCV after percutaneous LAAC from 2016 to 2022.

View Article and Find Full Text PDF

Background: Transesophageal echocardiography (TEE) and cardiac computed tomography angiography (CCTA) are currently utilized for left atrial appendage closure (LAAC) planning. During the recent global iodine contrast media shortage in 2022, cardiac magnetic resonance imaging (CMR) was utilized for the first time for LAAC planning. This study sought to assess the utility of CMR versus TEE for LAAC planning.

View Article and Find Full Text PDF

The sinoatrial node (SAN) is the primary pacemaker of the human heart. It is a single, elongated, 3-dimensional (3D) intramural fibrotic structure located at the junction of the superior vena cava intercaval region bordering the crista terminalis (CT). SAN activation originates in the intranodal pacemakers and is conducted to the atria through 1 or more discrete sinoatrial conduction pathways.

View Article and Find Full Text PDF
Article Synopsis
  • * Researchers conducted a transcriptomic analysis of SAN tissue from both HF and non-failing donor hearts to identify alterations in microRNAs (miRs) and mRNAs related to heart conditions.
  • * The study found significant changes in 47 miRs and 832 mRNAs affecting ion channels and neurotransmitter receptors, revealing potential molecular targets for treating SAN dysfunction and arrhythmias in HF patients.
View Article and Find Full Text PDF

Introduction: Defibrillation testing (DT) is recommended during the subcutaneous defibrillator (S-ICD) placement. We sought to compare 10 J shock impedance in sinus rhythm (SR) with 65 J defibrillation impedance and evaluate device position on a postimplant chest X-ray (CXR) using an intermuscular (IM) technique.

Methods: Consecutive S-ICD implantations between 12/2019 and 12/2020 at The Ohio State University were reviewed.

View Article and Find Full Text PDF

Objectives: The aim of this study was to assess temporal changes and clinical implications of peridevice leak (PDL) after left atrial appendage closure.

Background: Endocardial left atrial appendage closure devices are alternatives to long-term oral anticoagulation (OAC) for patients with atrial fibrillation. PDL >5 mm may prohibit discontinuation of OAC.

View Article and Find Full Text PDF

Background: Left ventricular (LV) endocardial pacing is a promising method to deliver cardiac resynchronization therapy (CRT). WiSE-CRT is a wireless LV endocardial pacing system, and delivers ultrasonic energy to an LV electrode.

Objective: The purpose of this study was to present short-term outcomes with the WiSE-CRT system in centers with no prior implanting experience.

View Article and Find Full Text PDF

As leadless pacing (LP) use is expected to increase, it becomes increasingly essential that operators become familiar with the tools and techniques needed to retrieve an LP successfully. The purpose of this review is to describe a stepwise approach for the successful retrieval of tine-based LP devices, including ways to minimize complications.

View Article and Find Full Text PDF

Objectives: This study reports resource use and economic implications of rhythm monitoring with subcutaneous cardiac rhythm monitors (SCRMs).

Background: SCRMs generate a substantial amount of data that requires timely adjudication for appropriate clinical care. Resource use for SCRM monitoring is not known.

View Article and Find Full Text PDF

Introduction: Frequent right AQ4ventricular pacing (≥40%) with a transvenous pacemaker (TVP) is associated with the risk of pacing-induced cardiomyopathy (PICM). Leadless pacemakers (LPs) have distinct physical and mechanical differences from TVP. The risk of PICM with LP is not known.

View Article and Find Full Text PDF

Atrial fibrillation (AF) occurrence and maintenance is associated with progressive remodeling of electrophysiological (repolarization and conduction) and 3D structural (fibrosis, fiber orientations, and wall thickness) features of the human atria. Significant diversity in AF etiology leads to heterogeneous arrhythmogenic electrophysiological and structural substrates within the 3D structure of the human atria. Since current clinical methods have yet to fully resolve the patient-specific arrhythmogenic substrates, mechanism-based AF treatments remain underdeveloped.

View Article and Find Full Text PDF

Leadless pacemakers (LPs) have emerged as a meaningful alternative to transvenous pacemakers for single-ventricular pacing. LPs eliminate many of lead- and pocket-associated complications observed with transvenous pacemakers. Owing to the lack of atrioventricular synchronous pacing until recently, the use of LP was generally reserved for those patients who either required minimal ventricular pacing or had permanent atrial fibrillation.

View Article and Find Full Text PDF