Publications by authors named "Grace Gwe-Ya Kim"

Background: The TG-51 protocol describes methods for obtaining reference dosimetry measurements for external photon and electron beams. Since the publication of TG-51 in 1999, research on reference dosimetry has allowed revisiting the procedures and data recommended in the protocol. An Addendum to TG-51 for electron beam reference dosimetry was published in 2024, which revises the formalism and procedures and provides updated data.

View Article and Find Full Text PDF

The purpose of this Medical Physics Practice Guideline (MPPG) is to describe the minimum level of medical physics support deemed prudent for the practice of linear-accelerator, photon-based (linac) stereotactic radiosurgery (SRS), and stereotactic body radiation therapy (SBRT) services. This report is an update of MPPG 9.a published in 2017.

View Article and Find Full Text PDF

An Addendum to the AAPM's TG-51 protocol for the determination of absorbed dose to water is presented for electron beams with energies between 4 MeV and 22 MeV ( ). This updated formalism allows simplified calibration procedures, including the use of calibrated cylindrical ionization chambers in all electron beams without the use of a gradient correction. New data are provided for electron beams based on Monte Carlo simulations.

View Article and Find Full Text PDF

Purpose: Meningiomas represent the most common primary tumor of the central nervous system. Current treatment options include surgical resection with or without adjuvant radiation therapy (RT), definitive RT, and observation. However, the radiation dose, fractionation, and margins used to treat patients with WHO grade 2 meningiomas, which account for approximately 20% of all meningiomas, are not clearly defined, and deciding on the optimal treatment modality can be challenging owing to the lack of randomized data.

View Article and Find Full Text PDF

Background: Simulated error training is a method to practice error detection in situations where the occurrence of error is low. Such is the case for the physics plan and chart review where a physicist may check several plans before encountering a significant problem. By simulating potentially hazardous errors, physicists can become familiar with how they manifest and learn from mistakes made during a simulated plan review.

View Article and Find Full Text PDF

Purpose: Brain metastases are common among adult patients with solid malignancies and are increasingly being treated with stereotactic radiosurgery (SRS). As more patients with brain metastases are becoming eligible for SRS, there is a need for practical review of patient selection and treatment considerations.

Methods And Materials: Two patient cases were identified to use as the foundation for a discussion of a wide and representative range of management principles: (A) SRS alone for 5 to 15 lesions and (B) a large single metastasis to be treated with pre- or postoperative SRS.

View Article and Find Full Text PDF

We compiled a sampling of the treatment techniques of intensity-modulated total body irradiation, total marrow irradiation and total marrow and lymphoid irradiation utilized by several centers across North America and Europe. This manuscript does not serve as a consensus guideline, but rather is meant to serve as a convenient reference for centers that are considering starting an intensity-modulated program.

View Article and Find Full Text PDF

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education, and professional practice of medical physics. The AAPM has more than 8000 members and is the principal organization of medical physicists in the US. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the US.

View Article and Find Full Text PDF

Online adaptive radiotherapy platforms present a unique challenge for commissioning as guidance is lacking and specialized adaptive equipment, such as deformable phantoms, are rare. We designed a novel adaptive commissioning process consisting of end-to-end tests using standard clinical resources. These tests were designed to simulate anatomical changes regularly observed at patient treatments.

View Article and Find Full Text PDF

Practical guidelines that are not explicit in the TG-51 protocol and its Addendum for photon beam dosimetry are presented for the implementation of the TG-51 protocol for reference dosimetry of external high-energy photon and electron beams. These guidelines pertain to: (i) measurement of depth-ionization curves required to obtain beam quality specifiers for the selection of beam quality conversion factors, (ii) considerations for the dosimetry system and specifications of a reference-class ionization chamber, (iii) commissioning a dosimetry system and frequency of measurements, (iv) positioning/aligning the water tank and ionization chamber for depth ionization and reference dose measurements, (v) requirements for ancillary equipment needed to measure charge (triaxial cables and electrometers) and to correct for environmental conditions, and (vi) translation from dose at the reference depth to that at the depth required by the treatment planning system. Procedures are identified to achieve the most accurate results (errors up to 8% have been observed) and, where applicable, a commonly used simplified procedure is described and the impact on reference dosimetry measurements is discussed so that the medical physicist can be informed on where to allocate resources.

View Article and Find Full Text PDF
Article Synopsis
  • Task Group 262 was established to create guidelines for the safe and effective use of Radiation Oncology electronic medical records (RO-EMR) since there was no existing consensus document on this topic.
  • The guidelines cover areas such as implementation, training, quality assurance, and the use of RO-EMR as an information repository and workflow manager, as well as specific applications for brachytherapy and nonstandard treatments.
  • The report was based on a comprehensive literature review, surveys of task group members’ practices, an AAPM membership survey, and general consensus from the group.
View Article and Find Full Text PDF

The purpose of this report is to provide detailed guidance on the dosimetry of the INTRABEAM® (Carl Zeiss Medical AG, Jena, Germany) electronic brachytherapy (eBT) system as it stands at the present time. This report has been developed by the members of American Association of Physicists in Medicine (AAPM) Task Group 292 and endorsed by the AAPM. Members of AAPM Task Group 292 on Electronic-Brachytherapy Dosimetry have reviewed pertinent publications and user manuals regarding the INTRABEAM system dosimetry and manufacturer-supplied dose calculation protocols.

View Article and Find Full Text PDF

Background: While the review of radiotherapy treatment plans and charts by a medical physicist is a key component of safe, high-quality care, very few specific recommendations currently exist for this task.

Aims: The goal of TG-275 is to provide practical, evidence-based recommendations on physics plan and chart review for radiation therapy. While this report is aimed mainly at medical physicists, others may benefit including dosimetrists, radiation therapists, physicians and other professionals interested in quality management.

View Article and Find Full Text PDF