J Clin Oncol
August 2023
Purpose: To determine whether addition of external beam radiation therapy (EBRT) to brachytherapy (BT) (COMBO) compared with BT alone would improve 5-year freedom from progression (FFP) in intermediate-risk prostate cancer.
Methods: Men with prostate cancer stage cT1c-T2bN0M0, Gleason Score (GS) 2-6 and prostate-specific antigen (PSA) 10-20 or GS 7, and PSA < 10 were eligible. The COMBO arm was EBRT (45 Gy in 25 fractions) to prostate and seminal vesicles followed by BT prostate boost (110 Gy if 125-Iodine, 100 Gy if 103-Pd).
Health Technol (Berl)
April 2022
As a profession, medical physics combines an advanced understanding of physics and math with knowledge of biology, anatomy and physiology. Consequently, rigorous education and training is required to assure that medical physicists have the requisite fundamental knowledge, specialized technical skills, and clinical understanding to contribute to the medical care of patients safely. There is, therefore, an interest in standardizing the educational pathways and in developing mechanisms to assure that competency is achieved and maintained.
View Article and Find Full Text PDFRecent publications show that some patients receive high cumulative radiation doses from recurrent CT examinations. Most of these patients had a diagnosis of malignancy, meaning that there was a likelihood that they would receive radiation therapy, possibly with image guidance. Patients receiving X-ray-based image-guided radiation therapy (IGRT) receive even more imaging dose, including to volumes of tissue outside the tumor target volume.
View Article and Find Full Text PDFPhys Med Biol
October 2019
Radiation therapy in the presence of a strong magnetic field is known to cause regions of enhanced and reduced dose at interfaces of materials with varying densities, in a phenomenon known as the electron return effect (ERE). In this study, a novel low-density gel dosimeter was developed to simulate lung tissue and was used to measure the ERE at the lung-soft tissue interface. Low-density gel dosimeters were developed with Fricke xylenol orange gelatin (FXG) and ferrous oxide xylenol orange (FOX) gels mixed with polystyrene foam beads of various sizes.
View Article and Find Full Text PDFIntrafraction motion (i.e. motion occurring during a treatment session) can play a pivotal role in the success of abdominal and thoracic radiation therapy.
View Article and Find Full Text PDFJ Med Phys
January 2018
This analysis estimated secondary cancer risks after volumetric modulated arc therapy (VMAT) and compared those risks to the risks associated with other modalities of head-and-neck (H&N) radiotherapy. Images of H&N anthropomorphic phantom were acquired with a computed tomography scanner and exported via digital imaging and communications in medicine (DICOM) standards to a treatment planning system. Treatment plans were performed using a VMAT dual-arc technique, a nine-field intensity-modulated radiation therapy (IMRT) technique, and a four-field three-dimensional conformal therapy (3DCRT) technique.
View Article and Find Full Text PDFPhys Med Biol
February 2018
The integration of magnetic resonance imaging (MRI) with linear accelerators (linac) has enabled the use of 3D MR-visible gel dosimeters for real-time verification of volumetric dose distributions. Several iron-based radiochromic 3D gels were created in-house then imaged and irradiated in a pre-clinical 1.5 T-7 MV MR-Linac.
View Article and Find Full Text PDFPurpose: To assess the image quality, scatter, and leakage radiation of an integrated magnetic resonance linear accelerator (MR-LINAC or MRL) system.
Methods: A large American College of Radiology (ACR) magnetic resonance imaging (MRI) accreditation phantom was used to evaluate the MRI capabilities of the integrated MRL system compared with those of other diagnostic MRI systems. Multiple sets of T1 and T2/PD images were acquired with the linear accelerator positioned at various angles and with the radiation beam on and off.
Background And Purpose: The strong magnetic field of integrated magnetic resonance imaging (MRI) and radiation treatment systems influences secondary electrons resulting in changes in dose deposition in three dimensions. To fill the need for volumetric dose quality assurance, we investigated the effects of strong magnetic fields on 3D dosimeters for MR-image-guided radiation therapy (MR-IGRT) applications.
Material And Methods: There are currently three main categories of 3D dosimeters, and the following were used in this study: radiochromic plastic (PRESAGE®), radiochromic gel (FOX), and polymer gel (BANG™).
Since the publication of the 2004 update to the American Association of Physicists in Medicine (AAPM) Task Group No. 43 Report (TG-43U1) and its 2007 supplement (TG-43U1S1), several new low-energy photon-emitting brachytherapy sources have become available. Many of these sources have satisfied the AAPM prerequisites for routine clinical purposes and are posted on the Brachytherapy Source Registry managed jointly by the AAPM and the Imaging and Radiation Oncology Core Houston Quality Assurance Center (IROC Houston).
View Article and Find Full Text PDFPurpose: The Imaging and Radiation Oncology Core Houston (IROC-H) (formerly the Radiological Physics Center) has reported varying levels of agreement in their anthropomorphic phantom audits. There is reason to believe one source of error in this observed disagreement is the accuracy of the dose calculation algorithms and heterogeneity corrections used. To audit this component of the radiotherapy treatment process, an independent dose calculation tool is needed.
View Article and Find Full Text PDFAdvances in image-guided radiotherapy (RT) have allowed for dose escalation and more precise radiation treatment delivery. Each decade brings new imaging technologies to help improve RT patient setup. Currently, the most frequently used method of three-dimensional pre-treatment image verification is performed with cone beam CT.
View Article and Find Full Text PDFBrachytherapy is the use of radionuclides to treat malignancies or benign conditions by means of a radiation source placed close to or into the tumor or treatment site. This practice parameter refers only to the use of radionuclide brachytherapy. Brachytherapy alone or combined with external beam therapy plays an important role in the management and treatment of patients with cancer.
View Article and Find Full Text PDFJ Contemp Brachytherapy
June 2016
Purpose: Computed tomography (CT)-based prostate post-implant dosimetry allows for definitive seed localization but is associated with high interobserver variation in prostate contouring. Currently, magnetic resonance imaging (MRI)-based post-implant dosimetry allows for accurate anatomical delineation but is limited due to inconsistent seed localization. Encapsulated contrast agent markers were previously proposed to overcome the seed localization limitation on MRI images by placing hyperintense markers adjacent to hypointense seeds.
View Article and Find Full Text PDFPurpose: A dose calculation tool, which combines the accuracy of the dose planning method (DPM) Monte Carlo code and the versatility of a practical analytical multisource model, which was previously reported has been improved and validated for the Varian 6 and 10 MV linear accelerators (linacs). The calculation tool can be used to calculate doses in advanced clinical application studies. One shortcoming of current clinical trials that report dose from patient plans is the lack of a standardized dose calculation methodology.
View Article and Find Full Text PDFPurpose: For postimplant dosimetric assessment, computed tomography (CT) is commonly used to identify prostate brachytherapy seeds, at the expense of accurate anatomical contouring. Magnetic resonance imaging (MRI) is superior to CT for anatomical delineation, but identification of the negative-contrast seeds is challenging. Positive-contrast MRI markers were proposed to replace spacers to assist seed localization on MRI images.
View Article and Find Full Text PDFThe increasing complexity of modern radiation therapy planning and delivery challenges traditional prescriptive quality management (QM) methods, such as many of those included in guidelines published by organizations such as the AAPM, ASTRO, ACR, ESTRO, and IAEA. These prescriptive guidelines have traditionally focused on monitoring all aspects of the functional performance of radiotherapy (RT) equipment by comparing parameters against tolerances set at strict but achievable values. Many errors that occur in radiation oncology are not due to failures in devices and software; rather they are failures in workflow and process.
View Article and Find Full Text PDFInt J Radiat Oncol Biol Phys
July 2016
Because magnetic resonance imaging-guided radiation therapy (MRIgRT) offers exquisite soft tissue contrast and the ability to image tissues in arbitrary planes, the interest in this technology has increased dramatically in recent years. However, intrinsic geometric distortion stemming from both the system hardware and the magnetic properties of the patient affects MR images and compromises the spatial integrity of MRI-based radiation treatment planning, given that for real-time MRIgRT, precision within 2 mm is desired. In this article, we discuss the causes of geometric distortion, describe some well-known distortion correction algorithms, and review geometric distortion measurements from 12 studies, while taking into account relevant imaging parameters.
View Article and Find Full Text PDFAlthough a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used in the evaluation of innovative devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining the equivalence of the innovative treatment modality to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of innovative radiotherapy devices or applications is a critical part in which physicists should be actively involved.
View Article and Find Full Text PDFConventional proton beam range verification using positron emission tomography (PET) relies on tissue activation alone and therefore requires particle therapy PET whose installation can represent a large financial burden for many centers. Previously, we showed the feasibility of developing patient implantable markers using high proton cross-section materials ((18)O, Cu, and (68)Zn) for in vivo proton range verification using conventional PET scanners. In this technical note, we characterize those materials to test their usability in more clinically relevant conditions.
View Article and Find Full Text PDFAnn Surg Oncol
December 2015
Background: Local tumor control (LC), overall survival (OS), symptom palliation, and late toxicity for patients with locally recurrent anorectal cancer treated with a computed tomography (CT)-guided interstitial brachytherapy implant were examined.
Methods: The medical records of 20 consecutive patients who had received interstitial brachytherapy for locally recurrent anorectal cancer from 2000 through 2012 were reviewed. Seventeen patients (85 %) had rectal cancer and three had anal cancer [median follow-up time for living patients, 23 months (range 13-132)].
Purpose: Treatment option of stereotactic radiosurgery versus whole brain radiotherapy for multiple brain metastases (>10) is an ongoing debate. Detailed dosimetric and biological information are presented in this study to investigate the possible clinical outcomes.Materials and Methods: Nine patients with multiple brain metastases (11-25) underwent stereotactic radiosurgery.
View Article and Find Full Text PDFThis study evaluated the secondary cancer risk from volumetric-modulated arc therapy (VMAT) for spine radiotherapy compared with intensity-modulated radiotherapy (IMRT) and 3-dimensional conformal radiotherapy (3DCRT). Computed tomography images of an Radiological Physics Center spine anthropomorphic phantom were exported to a treatment planning system (Pinnacle(3), version 9.4).
View Article and Find Full Text PDF