Electromagnetic metasurfaces offer a route to exotic, customised material properties that are not found in nature. However, in practice these artificial materials often do not live up to the promise of their design, limited by a myriad of fabrication challenges and defects. Global responses, such as transmission or reflection spectra, cannot distinguish different defect types, while scanning point measurements are impractical for materials which can contain thousands of individual meta-atoms.

View Article and Find Full Text PDF

The dynamic scattering of light impacts sensing and communication technologies throughout the electromagnetic spectrum. Here we introduce a new way to control the propagation of light through time-varying complex media. Our strategy is based on the observation that in many dynamic scattering systems, some parts of the medium will change configuration more slowly than others.

View Article and Find Full Text PDF

In this paper we investigate the application of phase-shifting digital holography for the real-time characterization of electromagnetic sources in the THz frequency range. We use an off-the-shelf terahertz detector array composed of power-sensitive pixels, over an area of , to record intensity interferograms cast between the coherent radiation emitted from a reference source and an unknown antenna under test. This approach parallelizes the acquisition process with respect to conventional near-field point scanning methods, reducing the measurement time by orders of magnitude.

View Article and Find Full Text PDF

Optical tweezers enable noncontact trapping of microscale objects using light. It is not known how tightly it is possible to three-dimensionally (3D) trap microparticles with a given photon budget. Reaching this elusive limit would enable maximally stiff particle trapping for precision measurements on the nanoscale and photon-efficient tweezing of light-sensitive objects.

View Article and Find Full Text PDF

Millimeter and terahertz wave imaging has emerged as a powerful tool for applications such as security screening, biomedical imaging, and material analysis. However, intensity images alone are often insufficient for detecting variations in the dielectric constant of a sample, and extraction of material properties without additional phase information requires extensive prior knowledge of the sample. Digital holography provides a means for intensity-only detectors to reconstruct both amplitude and phase images.

View Article and Find Full Text PDF

Time-of-flight three-dimensional (3D) imaging has applications that range from industrial inspection to motion tracking. Depth is recovered by measuring the round-trip flight time of laser pulses, typically using collection optics of several centimeters in diameter. We demonstrate near–video-rate 3D imaging through multimode fibers with a total aperture of several hundred micrometers.

View Article and Find Full Text PDF

When light propagates through opaque material, the spatial information it holds becomes scrambled, but not necessarily lost. Two classes of techniques have emerged to recover this information: methods relying on optical memory effects, and transmission matrix (TM) approaches. Here we develop a general framework describing the nature of memory effects in structures of arbitrary geometry.

View Article and Find Full Text PDF

The measurement of the optical transmission matrix (TM) of an opaque material is an advanced form of space-variant aberration correction. Beyond imaging, TM-based methods are emerging in a range of fields, including optical communications, micro-manipulation, and computing. In many cases, the TM is very sensitive to perturbations in the configuration of the scattering medium it represents.

View Article and Find Full Text PDF

The spatial information carried by light is scrambled when it propagates through a scattering medium, such as frosted glass, biological tissue, turbulent air, or multimode optical fibres. Digital optical phase conjugation (DOPC) is a technique that 'pre-aberrates' an illuminating wavefront to compensate for scatterer induced distortion. DOPC systems act as phase-conjugate mirrors: they require a camera to holographically record a distorted wavefront emanating from the scatterer and a spatial light modulator (SLM) to synthesize a phase conjugate of the measured wavefront, which is sent back through the scatterer thus creating a time-reversed copy of the original optical field.

View Article and Find Full Text PDF

The thin and flexible nature of optical fibres often makes them the ideal technology to view biological processes in-vivo, but current microendoscopic approaches are limited in spatial resolution. Here, we demonstrate a route to high resolution microendoscopy using a multicore fibre (MCF) with an adiabatic multimode-to-single-mode "photonic lantern" transition formed at the distal end by tapering. We show that distinct multimode patterns of light can be projected from the output of the lantern by individually exciting the single-mode MCF cores, and that these patterns are highly stable to fibre movement.

View Article and Find Full Text PDF

Single-pixel cameras reconstruct images from a stream of spatial projection measurements recorded with a single-element detector, which itself has no spatial resolution. This enables the creation of imaging systems that can take advantage of the ultra-fast response times of single-element detectors. Here we present a single-pixel camera with a temporal resolution of 200 ps in the visible and short-wave infrared wavelengths, used here to study the transit time of distinct spatial modes transmitted through few-mode and orbital angular momentum mode conserving optical fiber.

View Article and Find Full Text PDF

Optical tweezers are a highly versatile tool for exploration of the mesoscopic world, permitting non-contact manipulation of nanoscale objects. However, direct illumination with intense lasers restricts their use with live biological specimens, and limits the types of materials that can be trapped. Here we demonstrate an indirect optical trapping platform which circumvents these limitations by using hydrodynamic forces to exert nanoscale-precision control over aqueous particles, without directly illuminating them.

View Article and Find Full Text PDF

The linear Doppler shift is familiar as the rise and fall in pitch of a siren as it passes by. Less well known is the rotational Doppler shift, proportional to the rotation rate between source and receiver, multiplied by the angular momentum carried by the beam. In extreme cases the Doppler shift can be larger than the rest-frame frequency and for a red shift, the observed frequency then becomes "negative.

View Article and Find Full Text PDF

Digital micro-mirror devices (DMDs) have recently emerged as practical spatial light modulators (SLMs) for applications in photonics, primarily due to their modulation rates, which exceed by several orders of magnitude those of the already well-established nematic liquid crystal (LC)-based SLMs. This, however, comes at the expense of limited modulation depth and diffraction efficiency. Here we compare the beam-shaping fidelity of both technologies when applied to light control in complex environments, including an aberrated optical system, a highly scattering layer and a multimode optical fibre.

View Article and Find Full Text PDF

Spatial structuring of the intensity, phase and polarisation of light is useful in a wide variety of modern applications, from microscopy to optical communications. This shaping is most commonly achieved using liquid crystal spatial light modulators (LC-SLMs). However, the inherent chromatic dispersion of LC-SLMs when used as diffractive elements presents a challenge to the extension of such techniques from monochromatic to broadband light.

View Article and Find Full Text PDF

In contrast to conventional multipixel cameras, single-pixel cameras capture images using a single detector that measures the correlations between the scene and a set of patterns. However, these systems typically exhibit low frame rates, because to fully sample a scene in this way requires at least the same number of correlation measurements as the number of pixels in the reconstructed image. To mitigate this, a range of compressive sensing techniques have been developed which use a priori knowledge to reconstruct images from an undersampled measurement set.

View Article and Find Full Text PDF

We demonstrate a camera which can image methane gas at video rates, using only a single-pixel detector and structured illumination. The light source is an infrared laser diode operating at 1.651μm tuned to an absorption line of methane gas.

View Article and Find Full Text PDF

The dynamic spatial control of light fields is essential to a range of applications, from microscopy to optical micro-manipulation and communications. Here we describe the use of a single digital micro-mirror device (DMD) to generate and rapidly switch vector beams with spatially controllable intensity, phase and polarisation. We demonstrate local spatial control over linear, elliptical and circular polarisation, allowing the generation of radially and azimuthally polarised beams and Poincaré beams.

View Article and Find Full Text PDF

Single-pixel cameras provide a means to perform imaging at wavelengths where pixelated detector arrays are expensive or limited. The image is reconstructed from measurements of the correlation between the scene and a series of masks. Although there has been much research in the field in recent years, the fact that the signal-to-noise ratio (SNR) scales poorly with increasing resolution has been one of the main limitations prohibiting the uptake of such systems.

View Article and Find Full Text PDF

Literature examining magnetic resonance imaging (MRI) in acute spinal cord injury (SCI) has focused on cervical SCI. Reproducible systems have been developed for MRI-based grading; however, it is unclear how they apply to thoracic SCI. Our hypothesis is that MRI measures will group as coherent multivariate principal component (PC) ensembles, and that distinct PCs and individual variables will show discriminant validity for predicting early impairment in thoracic SCI.

View Article and Find Full Text PDF

Object: In this report, the authors describe the pathological changes in the human trigeminal nerve after Gamma Knife radiosurgery.

Methods: Three trigeminal nerves of patients with multiple sclerosis (MS)-related trigeminal neuralgia (MSTN) after Gamma Knife radiosurgery and other ablative procedures were examined by a neuropathologist. These cases were compared with 3 patients with typical TN who underwent partial surgical rhizotomy following recurrent symptoms after gasserian injury procedures, as well as with autopsy specimens from patients with and without MSTN.

View Article and Find Full Text PDF

The ability to rapidly switch between orbital angular momentum modes of light has important implications for future classical and quantum systems. In general, orbital angular momentum beams are generated using free-space bulk optical components where the fastest reconfiguration of such systems is around a millisecond using spatial light modulators. In this work, an extremely compact optical vortex emitter is demonstrated with the ability to actively tune between different orbital angular momentum modes.