Patients with chronic obstructive pulmonary disease (COPD) often experience acute exacerbations characterized by elevated neutrophilic inflammation in the lungs. Currently, this condition is diagnosed through visual inspection of sputum color and volume, a method prone to personal bias and unsuitable for patients who are unable to expectorate spontaneously. In this manuscript, we present a novel approach for measuring and monitoring exhaled myeloperoxidase (MPO), a biomarker of neutrophilic airway inflammation, without the need for sputum analysis.
View Article and Find Full Text PDFBackground: Ramp lesions, located in the posterior horn of the medial meniscus, are commonly associated with anterior cruciate ligament (ACL) injuries and contribute to knee instability if untreated. Traditional repair methods use posteromedial portals, but newer approaches, such as the all-inside technique through anterior arthroscopic portals with pie-crusting of the posterior oblique ligament (POL), offer improved access and reduced morbidity. This study aimed to assess the clinical outcomes, return-to-sport rates, and failure rates of this technique compared to established methods.
View Article and Find Full Text PDFIn this article we introduce a multirange analytical device that extends the dynamic range of nanoparticle-based immunoassays thanks to a multisensor design. Multirange devices contain low- and high-range sensors in the same analytical platform. The low-range sensor defines the limit of detection and quantifies low concentrated analytes, whereas the high-range sensor defines the upper limit of the dynamic range.
View Article and Find Full Text PDFBiosens Bioelectron
August 2024
Origami biosensors leverage paper foldability to develop total analysis systems integrated in a single piece of paper. This capability can also be utilized to incorporate additional features that would be difficult to achieve with rigid substrates. In this article, we report a new design for 3D origami biosensors called OriPlex, which leverages the foldability of filter paper for the multiplexed detection of bacterial pathogens.
View Article and Find Full Text PDFIntroduction: Common Variable Immunodeficiency (CVID) patients are characterized by hypogammaglobulinemia and poor response to vaccination due to deficient generation of memory and antibody-secreting B cells. B lymphocytes are essential for the development of humoral immune responses, and mitochondrial function, hreactive oxygen species (ROS) production and autophagy are crucial for determining B-cell fate. However, the role of those basic cell functions in the differentiation of human B cells remains poorly investigated.
View Article and Find Full Text PDFThis paper introduces the design of a reconfigurable transmitarray operating within the D-band frequency range (110-170 GHz). The transmitarray unit cell is composed of three metal layers and two quartz dielectric substrates. It achieves a 1-bit phase shift resolution through the alternating states of two innovative switches integrated into the active transmitting patch of the unit cell.
View Article and Find Full Text PDFDetecting sputum pyocyanin (PYO) with a competitive immunoassay is a promising approach for diagnosing Pseudomonas aeruginosa respiratory infections. However, it is not possible to perform a negative control to evaluate matrix-effects in competitive immunoassays, and the highly complex sputum matrix often interferes with target detection. Here, we show that these issues are alleviated by performing competitive immunoassays with a paper biosensor.
View Article and Find Full Text PDF() is a pathogen that persistently colonizes the respiratory tract of patients with chronic lung diseases. The risk of acquiring a chronic infection can be minimized by rapidly detecting the pathogen in the patient's airways and promptly administrating adequate antibiotics. However, the rapid detection of in the lungs involves the analysis of sputum, which is a highly complex matrix that is not always available.
View Article and Find Full Text PDFPurpose: Extensor mechanism disruption following total knee arthroplasty has a prevalence ranging from 0.3 to 3%. Its management is challenging, especially in case of associated infection of the prosthetic implant.
View Article and Find Full Text PDFBackground: Phenotyping sputum-resident leukocytes and evaluating their functional status are essential analyses for exploring the cellular basis of pathological processes in the lungs, and flow cytometry is widely recognized as the gold-standard technique to address them. However, sputum-resident leukocytes are found in respiratory samples which need to be liquefied prior to cytometric analysis. Traditional liquefying procedures involve the use of a reducing agent such as dithiothreitol (DTT) in temperature-controlled conditions, which does not homogenize respiratory samples efficiently and impairs cell viability and functionality.
View Article and Find Full Text PDFSens Actuators B Chem
December 2022
Stratifying patients according to disease severity has been a major hurdle during the COVID-19 pandemic. This usually requires evaluating the levels of several biomarkers, which may be cumbersome when rapid decisions are required. In this manuscript we show that a single nanoparticle aggregation test can be used to distinguish patients that require intensive care from those that have already been discharged from the intensive care unit (ICU).
View Article and Find Full Text PDFInfections caused by bacteria that produce β-lactamases (BLs) are a major problem in hospital settings. The phenotypic detection of these bacterial strains requires culturing samples prior to analysis. This procedure may take up to 72 h, and therefore it cannot be used to guide the administration of the first antibiotic regimen.
View Article and Find Full Text PDFMeasuring the colorimetric signals produced by the biospecific accumulation of colorimetric probes and recording the results is a key feature for next-generation paper-based rapid tests. Manual processing of these tests is time-consuming and prone to a loss of accuracy when interpreting faint and patchy signals. Proprietary, closed-source readers and software companies offering automated smartphone-based assay readings have both been criticized for interoperability issues.
View Article and Find Full Text PDFPurpose: The purposes of this study were to determine demographics and characteristics of patients who underwent spacer exchange for persistent infection in the setting of two-stage arthroplasty for periprosthetic joint infection, to describe the microbiology of pathogens involved, to analyze survivorship free from infection in these patients.
Methods: The institutional prospectively collected database was reviewed to enroll patients with minimum 2 years follow-up. Patients who underwent two-stage procedure for septic arthritis were excluded, as were patients who had spacer fracture or dislocation.
Hyperdegranulation of neutrophilic granulocytes is a common finding in sepsis that directly contributes to the heightened immune response leading to organ dysfunction. Currently, cell degranulation is detected by flow cytometry, which requires large infrastructure that is not always available at the point of care. Here, we propose a plasmonic assay for detecting the degranulation status of septic cells colorimetrically.
View Article and Find Full Text PDFBackground: Total knee arthroplasty is a reliable procedure able to reduce pain and disability in patients suffering from osteoarthritis. However, a considerable percentage of patients still experiences unsatisfactory results. Medial pivot total knee arthroplasty has been introduced in the clinical practice to overcome problems related with classic design implants and better mimic native knee kinematics.
View Article and Find Full Text PDFLung IL-6 is a promising biomarker for predicting respiratory failure during pulmonary infections. This biomarker is found in respiratory samples which need to be liquefied prior to analysis. Traditional liquefying methods use reducing agents such as dithiothreitol (DTT).
View Article and Find Full Text PDFDetecting SARS-CoV-2 antigens in respiratory tract samples has become a widespread method for screening new SARS-CoV-2 infections. This requires a nasopharyngeal swab performed by a trained healthcare worker, which puts strain on saturated healthcare services. In this manuscript we describe a new approach for non-invasive COVID-19 diagnosis.
View Article and Find Full Text PDFPurpose: Septic arthritis of the native joint is challenging for orthopedic surgeons because it may lead to wide bone defects and severe impairment of joint function. This study aimed to analyze clinical functional outcomes, the rate of infection eradication, and survival of implants of patients who underwent two-stage arthroplasty for septic arthritis of the hip and knee.
Methods: A retrospective single-centre analysis was conducted of patients treated for septic arthritis of the hip and knee joints through a two-stage surgery between 2012 and 2015.
Lung-secreted IgG and IgM antibodies are valuable biomarkers for monitoring the local immune response against respiratory infections. These biomarkers are found in lower airway secretions that need to be liquefied prior to analysis. Traditional methods for sample liquefaction rely on reducing disulfide bonds, which may damage the structure of the biomarkers and hamper their immunodetection.
View Article and Find Full Text PDFDecentralizing COVID-19 care reduces contagions and affords a better use of hospital resources. We introduce biosensors aimed at detecting severe cases of COVID-19 in decentralized healthcare settings. They consist of a paper immunosensor interfaced with a smartphone.
View Article and Find Full Text PDFRespiratory infections caused by multi-drug-resistant often yield poor outcomes if not detected right away. However, detecting this pathogen in respiratory samples with a rapid diagnostic test is challenging because the protective biofilms created by the pathogen are themselves surrounded by a high-viscosity sputum matrix. Here, we introduce a method for liquefying respiratory samples and disrupting bacterial biofilms on the spot within a minute.
View Article and Find Full Text PDFBackground: Peri-prosthetic shoulder infection (PSI), a highly disabling complication of shoulder arthroplasty, often requires additional surgery and prolonged antibiotic therapy. Of strategies proposed to manage this devastating condition, the use of cement spacers, perhaps even as a definitive treatment, is debated.
Questions/purposes: We sought to systematically review the literature on antibiotic-loaded cement spacers as a viable, perhaps definitive, treatment for PSI, evaluating the eradication rates, mechanical reliability, and functional results related to its use.
Urinary tract infections (UTI) have a high prevalence and can yield poor patient outcomes if they progress to urosepsis. Here we introduce mobile origami biosensors that detect UTIs caused by E. coli at the bedside in less than 7 minutes.
View Article and Find Full Text PDF