A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Plasma glucose and HbA1c discrepancy may indicate hemoglobinopathy: a case series. | LitMetric

Plasma glucose and HbA1c discrepancy may indicate hemoglobinopathy: a case series.

Curr Med Res Opin

Department of Internal Medicine, Taksim Training and Research Hospital, Istanbul, Turkey.

Published: September 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Diabetes Mellitus is a chronic disease characterised by elevated plasma glucose (PG) levels. HbA1c has been widely utilized for diabetes diagnosis. However, certain conditions restrict its use. In such cases, plasma glucose (PG) measurements and self-monitoring blood glucose (SMBG) are recommended. This case series highlights the importance of considering both HbA1c and PG or SMBG in the evaluation of patients with diabetes.

Case Report: This case series presents three cases of patients with diabetes who exhibited a discrepancy between PG and HbA1c levels. Only one patient demonstrated isolated microcytosis, while the remaining two had completely normal hematologic profiles. Due to this discrepancy, hemoglobin electrophoresis was conducted, revealing various hemoglobinopathies in all cases.

Conclusion: For patients with discrepancies between PG levels and HbA1c, we suggest a thorough evaluation that includes consideration of potential hemoglobinopathies. These hemoglobin variants can present with isolated microcytosis or entirely normal hematologic parameters and may lead to falsely low HbA1c values. In cases of discordance between PG and HbA1c, hemoglobin electrophoresis can serve as a valuable diagnostic tool. Identifying hemoglobinopathies before determining treatment regimens can help mitigate the risk of complications from inadequate treatment, and awareness of HbA1c limitations allows clinicians to use both HbA1c and PG/SMBG to optimize diabetes management and minimize the risk of diabetic complications.

Download full-text PDF

Source
http://dx.doi.org/10.1080/03007995.2025.2557519DOI Listing

Publication Analysis

Top Keywords

plasma glucose
12
case series
12
hba1c
9
levels hba1c
8
isolated microcytosis
8
normal hematologic
8
hemoglobin electrophoresis
8
glucose hba1c
4
hba1c discrepancy
4
discrepancy indicate
4

Similar Publications