Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Objective: To evaluate the measurement accuracy of 2 swept-source optical biometers, the IOLMaster 700 and the Revo FC 130, in patients diagnosed with cataracts.
Methods: We conducted a prospective, observational and comparative study in patients older than 40 years with cataracts. A single operator performed optical biometry using both devices during the same session. Cataract grading was conducted using the Lens Opacities Classification System III.
Results: Biometric measurements were obtained from the 504 eyes of 279 patients, with a mean age of 70.93 ± 8.41 years. Statistically significant differences were found between the IOLMaster 700 and Revo FC 130 in the following parameters: mean keratometry (43.53 ± 1.56 vs 44.27 ± 1.68 diopters), total average keratometry and mean keratometry (43.56 ± 1.55 D vs 44.27 ± 1.67 diopters), white-to-white distance (11.98 ± 0.52 vs 12.66 ± 0.73 mm), and lens thickness (4.53 ± 0.40 vs 4.60 ± 0.40 mm). No significant differences were found in axial length (23.31 ± 0.96 vs 23.25 ± 1.01 mm) or anterior chamber depth (3.02 ± 0.38 vs 3.02 ± 0.37 mm), which were not clinically relevant. No statistically significant differences were found between the IOLMaster 700 measurements of total mean keratometry (43.53 ± 1.56 diopters) and mean keratometry (43.56 ± 1.56 diopters).
Conclusions: Although most measurements do not reveal any clinically relevant differences, the 2 devices should not be used interchangeably, mainly due to variations in keratometry readings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.oftale.2025.09.002 | DOI Listing |