A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Using Explainable AI to Characterize Features in the Mirai Mammographic Breast Cancer Risk Prediction Model. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose To evaluate whether features extracted by Mirai can be aligned with mammographic observations, and contribute meaningfully to the prediction. Materials and Methods This retrospective study examined the correlation of 512 Mirai features with mammographic observations in terms of receptive field and anatomic location. A total of 29,374 screening examinations with mammograms (10,415 women, mean age at examination 60 [SD: 11] years) from the EMBED Dataset (2013-2020) were used to evaluate feature importance using a feature-centric explainable AI pipeline. Risk prediction was evaluated using only calcification features (CalcMirai) or mass features (MassMirai) against Mirai. Performance was assessed in screening and screen-negative (time-to-cancer > 6 months) populations using the area under the receiver operating characteristic curve (AUC). Results Eighteen calcification features and 18 mass features were selected for CalcMirai and MassMirai, respectively. Both CalcMirai and MassMirai had lower performance than Mirai in lesion detection (screening population, 1-year AUC: Mirai, 0.81 [95% CI: 0.78, 0.84], CalcMirai, 0.76 [95% CI: 0.73, 0.80]; MassMirai, 0.74 [95% CI: 0.71, 0.78]; values < 0.001). In risk prediction, there was no evidence of a difference in performance between CalcMirai and Mirai (screen-negative population, 5-year AUC: Mirai, 0.66 [95% CI: 0.63, 0.69], CalcMirai, 0.66 [95% CI: 0.64, 0.69]; value: 0.71); however, MassMirai achieved lower performance than Mirai (AUC, 0.57 [95% CI: 0.54, 0.60]; value < .001). Radiologist review of calcification features confirmed Mirai's use of benign calcification in risk prediction. Conclusion The explainable AI pipeline demonstrated that Mirai implicitly learned to identify mammographic lesion features, particularly calcifications, for lesion detection and risk prediction. ©RSNA, 2025.

Download full-text PDF

Source
http://dx.doi.org/10.1148/ryai.240417DOI Listing

Publication Analysis

Top Keywords

risk prediction
20
calcification features
12
mirai
10
features
9
mammographic observations
8
explainable pipeline
8
mass features
8
calcmirai massmirai
8
lower performance
8
performance mirai
8

Similar Publications