Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Unlabelled: Pathogens pose significant threats to biosecurity and environmental health due to their potential for widespread outbreaks. Effective pathogen detection requires methods that are rapid, sensitive, specific, and informative. Here, we proposed a multiplex visual detection system that integrated ultrafast polymerase chain reaction (PCR) and molecular beacons, allowing the simultaneous detection of three pathogens in a one-pot reaction. The ultrafast PCR protocol employed cycles of just 7 s each, allowing the entire process-from sampling to result-to be completed within only 10 min. Molecular beacons hybridized with target sequences during ultrafast PCR, generating fluorescence signals that are visually detectable without specialized equipment. Additionally, we developed a compact, portable cartridge integrated with online software for fluorescence visualization and direct result output, eliminating the need for bulky instruments and specialized personnel, thereby facilitating point-of-care testing (POCT). The method demonstrated high specificity and sensitivity, with a limit of detection (LOD) as low as 23 copies per reaction. It achieved a 100% positive detection rate in practical applications, performing comparably to standard PCR. Furthermore, the method effectively identified low concentrations of pathogens in animal infection samples. This ultrafast, highly sensitive, specific, and informative method shows significant potential for POCT applications, including food safety monitoring and clinical diagnostics.
Supplementary Information: The online version contains supplementary material available at 10.1007/s43657-024-00216-3.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12390895 | PMC |
http://dx.doi.org/10.1007/s43657-024-00216-3 | DOI Listing |