A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

MVPCR: Multiplex Visual Detection Strategy Based on Ultrafast PCR for Point-of-Care Pathogens Detection Within 10 Min. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Unlabelled: Pathogens pose significant threats to biosecurity and environmental health due to their potential for widespread outbreaks. Effective pathogen detection requires methods that are rapid, sensitive, specific, and informative. Here, we proposed a multiplex visual detection system that integrated ultrafast polymerase chain reaction (PCR) and molecular beacons, allowing the simultaneous detection of three pathogens in a one-pot reaction. The ultrafast PCR protocol employed cycles of just 7 s each, allowing the entire process-from sampling to result-to be completed within only 10 min. Molecular beacons hybridized with target sequences during ultrafast PCR, generating fluorescence signals that are visually detectable without specialized equipment. Additionally, we developed a compact, portable cartridge integrated with online software for fluorescence visualization and direct result output, eliminating the need for bulky instruments and specialized personnel, thereby facilitating point-of-care testing (POCT). The method demonstrated high specificity and sensitivity, with a limit of detection (LOD) as low as 23 copies per reaction. It achieved a 100% positive detection rate in practical applications, performing comparably to standard PCR. Furthermore, the method effectively identified low concentrations of pathogens in animal infection samples. This ultrafast, highly sensitive, specific, and informative method shows significant potential for POCT applications, including food safety monitoring and clinical diagnostics.

Supplementary Information: The online version contains supplementary material available at 10.1007/s43657-024-00216-3.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12390895PMC
http://dx.doi.org/10.1007/s43657-024-00216-3DOI Listing

Publication Analysis

Top Keywords

ultrafast pcr
12
multiplex visual
8
visual detection
8
sensitive specific
8
specific informative
8
molecular beacons
8
detection
7
ultrafast
5
pcr
5
mvpcr multiplex
4

Similar Publications