A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Comprehensive pre- and in-hospital near-infrared-spectroscopy (NIRS) monitoring after return of spontaneous circulation predicts neurological outcome following out-of-hospital cardiac arrest: a prospective observational study and literature review. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: An increase in regional cerebral oxygen saturation (rSO2) levels during advanced life support in patients with out-of-hospital cardiac arrest (OHCA) is associated with return of spontaneous circulation (ROSC) and can predict neurological outcome. Data from the post-ROSC phase are scarce but may predict clinical outcomes as well.

Methods: For this prospective observational study, we measured rSO2 via near-infrared spectroscopy (NIRS) in patients after ROSC following OHCA in both the pre- and in-hospital setting for up to 72 h. Patients were followed up for their post-ROSC treatment and outcomes. NIRS values were then compared between patients with favorable and non-favorable neurological outcomes, and cutoff values were assessed via receiver operating characteristic (ROC) and Classification and Regression Trees (CART) analyses. In addition, a narrative review on the topic was performed.

Results: Of the 27 included patients, 37% survived hospital discharge, and 26% showed favorable neurological outcomes (CPC 1 or 2). RSO2 was significantly higher in individuals with CPC 1/2 (67 [60-69] % vs. 59 [50-70] %;  = 0.049). This was even more pronounced for initial (= a mean of the first 5 min) NIRS values (70 [65-77] % vs. 57 [49-68] %;  = 0.025) and NIRS values rising in the first 10 min (43% vs. 5% of patients;  = 0.042). A ROC analysis for initial rSO2 showed a significant discriminatory power to predict CPC 1/2 (AUC = 0.789,  = 0.025), and both ROC and CART analyses suggested an optimal cutoff of approximately 62% rSO2.

Conclusion: We identified a potential RSO2 cutoff measured via NIRS in the post-ROSC phase after OHCA to predict favorable neurological outcomes. Initial values and rising trends may be more useful for prognostication than prolonged ICU measurements. These findings are consistent with previous literature and should prompt both larger clinical trials and consideration of this technology by resuscitation societies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12394502PMC
http://dx.doi.org/10.3389/fmed.2025.1590908DOI Listing

Publication Analysis

Top Keywords

nirs values
12
neurological outcomes
12
pre- in-hospital
8
return spontaneous
8
spontaneous circulation
8
neurological outcome
8
out-of-hospital cardiac
8
cardiac arrest
8
prospective observational
8
observational study
8

Similar Publications