98%
921
2 minutes
20
Mainstream approaches to spectral reconstruction primarily focus on Convolution- and Transformer-based architectures. However, CNN methods fall short in handling long-range dependencies, whereas Transformers are constrained by computational efficiency limitations. Therefore, constructing a efficient spectral reconstruction network while ensuring the quality of reconstructed hyperspectral images (HSIs) has become a major challenge. Recent breakthroughs in the state-space model (e.g., Mamba) have attracted significant attention from natural language processing to vision tasks due to its near-linear computational efficiency and superior performance, prompting our investigation into its potential for spectral reconstruction problems. To this end, we introduce the Gradient-integrated Mamba for Spectral Reconstruction from RGB Images, dubbed GMSR-Net. GMSR-Net is a lightweight model characterized by a global receptive field and linear computational complexity. Its core comprises multiple stacked Gradient Mamba (GM) blocks, each featuring a tri-branch structure. Building upon the efficient global feature representation from the Mamba, we further innovatively propose spatial gradient attention and spectral gradient attention to guide the reconstruction of spatial and spectral cues. GMSR-Net demonstrates a significant accuracy-efficiency trade-off, achieving state-of-the-art performance while markedly reducing the number of parameters and computational burdens. Compared to existing approaches, GMSR-Net slashes parameters and FLOPs by substantial margins of 8 times and 20 times, respectively. Code is available at https://github.com/wxy11-27/GMSR.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.neunet.2025.108020 | DOI Listing |
Electromagn Biol Med
September 2025
Laboratory of Biophysics of Sub-Cellular Structures, Scientific-Research Institute of Biology, Chair of Biophysics, Faculty of Biology, Yerevan State University, Yerevan, Armenia.
Effect of millimeter range electromagnetic waves (MM EMW) with the frequency 51.8 GHz on the interaction of DNA-specific ligands-intercalators acridine orange (AO) and methylene blue (MB) with bovine serum albumin (BSA) has been studied. The measurements were implemented by the spectroscopic methods that open new opportunities for such goals.
View Article and Find Full Text PDFInterv Neuroradiol
September 2025
Department of Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
PurposeTo evaluate the potential of Photon-Counting Detector CT Angiography (PCD-CTA) for the assessment of carotid and subclavian artery stents compared to digital subtraction angiography (DSA) and Duplex ultrasound (DUS).MethodsThis study is a single-center, retrospective analysis of consecutive patients treated with a stent for high grade stenosis of the extra-cranial carotid and the subclavian artery between April 2023 and May 2024. Polyenergetic images (PE), iodine and virtual monoenergetic images were performed at different keV levels (40 and 80) and with two body vascular reconstruction kernels (Bv56 and 72) with and without iterative metal artifact reduction.
View Article and Find Full Text PDFSkeletal Radiol
September 2025
Department of Radiology and Nuclear Medicine, University Medical Center Utrecht & Utrecht University, PO Box 85500, 3508 GA, Utrecht, the Netherlands.
Objectives: To evaluate whether dual-layer spectral computed tomography, compared with conventional CT, improves diagnostic accuracy for osteolytic vertebral metastases. Furthermore, to investigate the influence of dual-layer CT on the subjective visibility of metastases.
Materials And Methods: In this single-center retrospective study, consecutive patients with an untreated primary tumor who underwent dual-layer CT and either MRI or PET-CT as reference standard within 14 days were included.
Neural Netw
August 2025
National Key Laboratory of Information Systems Engineering, Changsha, 410000, China. Electronic address:
Graph contrastive learning seeks to improve the efficacy of graph representation learning by comparing various graph representations. Existing approaches predominantly rely on node attributes or structural information for contrastive analysis. However, in real-world applications, node attribute information can be incomplete or entirely absent, while structure-enhancement methods often generate false positive samples.
View Article and Find Full Text PDFPediatr Radiol
September 2025
Department of Radiology, University of Colorado School of Medicine/Department of Pediatric Radiology, Children's Hospital Colorado, 13123 East 16th Avenue, Box 125, Aurora, 80045, Colorado, USA.
Background: Previous studies have shown improved image quality in pediatric cardiac imaging using photon-counting detector CT (PCDCT). However, these studies did not evaluate image quality and radiation dose when utilizing the full spectral capabilities of PCDCT scanners. The full spectral capability of PCDCT scanners allows the generation of the entire array of mono-energetic reconstructions, virtual non-contrast (VNC) images, and iodine maps, which have potential advantages in evaluating complex congenital heart disease.
View Article and Find Full Text PDF