In Vivo Evaluation of ZnAg3-A New Bioabsorbable Material in Fracture Treatment Compared to Biodegradable Mg Alloys.

J Biomed Mater Res B Appl Biomater

G.E.R.N. Tissue Replacement, Regeneration & Neogenesis, Department of Orthopedics and Trauma Surgery, Medical Center-Albert-Ludwigs-University of Freiburg, Faculty of Medicine, Albert-Ludwigs-University of Freiburg, Freiburg, Germany.

Published: September 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Permanent implants, which are primarily used to treat fractures, are either removed during a subsequent procedure or remain in the body after being surgically inserted. Bioabsorbable implants are designed to be reabsorbed by the body, minimizing the risk of chronic infections or foreign body reactions. The qualification of a novel zinc-silver alloy containing 3.3 wt% silver (ZnAg3) as a bioabsorbable implant was investigated in this in vivo study on New Zealand white rabbits. The osteointegration of ZnAg3 pins and MAGNEZIX pins, which served as controls, was evaluated histomorphometrically and histologically at 4, 8, and 16-week intervals. The implant area and the osteoid area were measured in order to assess the degradation of the material as well as the bone formation. The histological evaluation included a cell count of osteogenic cells and a descriptive evaluation of the histological images. The animal trial was accompanied by frequent blood, urine, and X-ray tests. The results showed adequate degradation of ZnAg3 with an implant area of 93.92% ± 5.85% at week 16 and a sufficient number of osteogenic cells, allowing progressive osteointegration. In comparison, the MAGNEZIX pin degraded significantly faster and, after 16 weeks, diminished to 77.54% ± 13.59% of the original implant area. Furthermore, harmful hydrogen gas pockets were found, which correlated with reduced bone formation, represented by a lower cell count of osteoblasts after 4 weeks. ICP-OES measurements performed on the animals' blood samples did not reveal any increased metal ion concentrations above the tolerable level. Thus, ZnAg3 pins showed excellent results compared to MAGNEZIX pins, which are in clinical use as bioabsorbable implants.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.35647DOI Listing

Publication Analysis

Top Keywords

implant area
12
bioabsorbable implants
8
znag3 pins
8
magnezix pins
8
bone formation
8
cell count
8
osteogenic cells
8
vivo evaluation
4
evaluation znag3-a
4
bioabsorbable
4

Similar Publications

Background: Acetabular reconstruction is often challenging in revision hip arthroplasty, especially in the face of moderate to severe acetabular bone deficiency. In some severe bone defects, double-metal tantalum cups can improve the contact area between bone and implants, increase the surface area for bone ingrowth, and better restore the anatomical position of the acetabulum. Furthermore, with a good press-fit, the auxiliary screw has a minimal effect on acetabular cup stability.

View Article and Find Full Text PDF

Background: Atrial fibrillation (AF) and heart failure (HF) frequently coexist in patients, with the development of AF often preceding HF decompensation. We sought to evaluate whether daily remote monitoring of ICD parameters could predict AF occurrence using machine learning techniques in a real-world cohort.

Methods: Data from patients with primary prevention ICDs transmitted daily to the Northwell centralized remote monitoring center between 2012 and 2021 were extracted.

View Article and Find Full Text PDF

This study was performed to evaluate the amount of bone implant engagement (BIE) of zygomatic implants (ZIs) at the malar bone level and its correlation with the ZAGA classification (zygoma anatomy-guided approach). One hundred ZIs placed in 32 patients with severe maxillary atrophy using a fully digital protocol were assessed: 80 placed in pairs (40 anterior (AI), 40 posterior (PI)) and 20 as single ZIs (SI). The ZAGA classification was determined preoperatively.

View Article and Find Full Text PDF

Background: Recurrent Implantation Failure (RIF) is defined as the inability to establish pregnancy despite high-quality embryo transfer after the application of at least three consecutive in vitro fertilization (IVF)/intracytoplasmic sperm injection-embryo transfer procedures. Chromosomal abnormalities are one of the primary reasons for pregnancy failure, miscarriage, and birth defects in both natural conception and IVF pregnancies. This study was to evaluate the incidence of chromosomal abnormalities in peripheral blood samples from 100 couples who experienced RIF.

View Article and Find Full Text PDF

Subretinal injection of adeno-associated virus (AAV) is generally more efficacious and less inflammatory than intravitreal injection for retinal gene therapy. However, adverse events (e.g.

View Article and Find Full Text PDF