98%
921
2 minutes
20
The aim of this study was to establish reference values for the Five-Times-Sit-to-Stand Test (FTSST) in a large, population-representative sample from 14 European countries. Data were collected among 45,470 participants aged 50 + years, as part of the 5th wave of the Survey of Health, Ageing and Retirement in Europe. The reference values for the FTSST were calculated as the 5th, 10th, 20th, 30th, 40th, 50th, 60th, 70th, 80th, 90th, and the 95th weighted percentile. The analyses were stratified by age and sex. For females, the best performance on the FTSST was observed among the 50-54-year-olds (5th percentile = 18 s; 50th percentile = 10 s; 95th percentile = 6 s) and the worst among 85-89-year-olds and ≥ 90-year-olds (5th percentile = 28 s; 50th percentile = 15 s; 95th percentile = 9 s). For males, the best performance was observed among the 55-59-year-olds (5th percentile = 18 s; 50th percentile = 9 s; 95th percentile = 5 s). The worst performance for males was observed among ≥ 90-year-olds (5th percentile = 26 s; 50th percentile = 15 s; 95th percentile = 9 s), even though the 10th percentile was higher (poorer performance) among 85-89-year-olds. The reference values indicate poorer performance on the test among females and in older age groups. The provided reference values for FTSST can be used for health screening, surveillance, and intervention planning, as they enable an interpretation of test results according to sex and age.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11357-025-01863-8 | DOI Listing |
Arthritis Care Res (Hoboken)
September 2025
Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
Background: Interstitial lung disease (ILD) is a significant cause of morbidity and mortality in systemic sclerosis (SSc), particularly among Black patients. Pulmonary function tests (PFTs) are critical to screen for and monitor SSc-ILD. We examined whether race-specific and race-neutral PFT reference equations impact classification of restrictive lung disease (RLD) severity in Black and White patients with SSc.
View Article and Find Full Text PDFJ Dance Med Sci
September 2025
Universidade Federal do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil.
The aim of this study was to propose reference values for the Dynamic Evaluation Method of Lower Limb Joint Alignment (MADAAMI II). During the 2023 Joinville Dance Festival, 346 dancers (315 females and 31 males), aged between 15 and 58 years, with a minimum of 5 years of ballet experience, were randomly evaluated. The dancers were filmed performing the three-step sequence (demi plié, grand plié, and fondu) of the MADAAMI II, in the first foot position, with self-selected turnout and at 120 degrees.
View Article and Find Full Text PDFMagn Reson Med
September 2025
Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
Purpose: To develop and validate a fast, motion-robust, free-breathing abdominal 3D T1ρ mapping method by combining variable-density diamond radial k-space sampling with fast-MAPSS (magnetization-prepared angle-modulated partitioned-k-space spoiled gradient-echo snapshots).
Methods: 3D MAPSS T1ρ imaging was performed at 3T using five spin-lock time (TSL) pairs in phantom scans and three TSL pairs in nine healthy volunteers. Phantom experiments compared Cartesian sampling (reference) with stack-of-stars and diamond radial sampling.
J Vet Intern Med
September 2025
Department of Medicine and Epidemiology, School of Veterinary Medicine, University of California-Davis, Davis, California, USA.
Background: Echocardiographic reference intervals for Quarter Horses are infrequently reported.
Objectives: To provide standard echocardiographic measurements for sedentary Quarter Horses and evaluate the relationship between physical characteristics (body weight, age, sex) and echocardiographic measurements.
Animals: Forty-one sedentary Quarter Horses, free of cardiac disease, from a university research herd.
Aesthetic Plast Surg
September 2025
Department of Plastic and Cosmetic Surgery, Tongji Hospital, School of Medicine, Tongji University, No.389 Xincun Road, Shanghai, 200092, China.
Background: The integration of digital tools in aesthetic medicine has enhanced the precision of facial feature analysis. Using concepts like the Golden Ratio, these technologies enable more objective assessments of facial proportions and symmetry. The beauty scanner-face analyzer (BS-FA) app offers a digital approach to evaluate geometric proportions and facial alignment, providing valuable data for preoperative planning in plastic surgery and aesthetic treatments.
View Article and Find Full Text PDF