A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Field Calibration of the Optical Properties of Pedestrian Targets in Autonomous Emergency Braking Tests Using a Three-Dimensional Multi-Faceted Standard Body. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

To address the growing need for field calibration of the optical properties of pedestrian targets used in autonomous emergency braking (AEB) tests, a novel three-dimensional multi-faceted standard body (TDMFSB) was developed. A camera-based analytical algorithm was proposed to evaluate the bidirectional reflectance distribution function (BRDF) characteristics of pedestrian targets. Additionally, a field calibration method applied in AEB testing scenarios (CPFAO and CPLA protocols) on one new and one aged typical pedestrian target of the same type revealed a 21% decrease in the BRDF uniformity of the aged target compared to the new one, confirming optical degradation due to repeated "crash-scatter-reassembly" cycles. The surface wear of the aged target on the side facing the vehicle produced a smoother surface, increasing its BRDF magnitude by 25% compared to the new target and making it easily detectable by the vehicle's perception system. This led to "reverse scoring," a safety risk in performance evaluation, necessitating timely calibration of AEB pedestrian targets to ensure reliable test results. The findings provide valuable insights into the development of regulatory techniques, evaluation standards, and technical specifications for test targets and offer a practical path toward full-life-cycle traceability and quality control.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12390461PMC
http://dx.doi.org/10.3390/s25165145DOI Listing

Publication Analysis

Top Keywords

pedestrian targets
16
field calibration
12
calibration optical
8
optical properties
8
properties pedestrian
8
targets autonomous
8
autonomous emergency
8
emergency braking
8
three-dimensional multi-faceted
8
multi-faceted standard
8

Similar Publications