Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
: Patients with end-stage renal disease (ESRD) are at elevated risk for device-related complications following pacemaker implantation. Leadless pacemakers (LPMs) offer theoretical advantages over transvenous pacemakers (TVPs), but their safety and efficacy in this high-risk population remain unclear. Our aim was to compare clinical outcomes and complication profiles between leadless and transvenous pacemakers in patients with ESRD. : We conducted a systematic review and meta-analysis according to PRISMA guidelines, including three retrospective studies comparing LPMs and TVPs in ESRD patients. The primary endpoint was overall complications post-implantation. Secondary outcomes included early mortality (within 30 days), access site complications, device-related events, thrombotic events, and respiratory complications. A random-effects model was used to pool odds ratios (ORs) and 95% confidence intervals (CIs). : Three studies comprising 10.075 ESRD patients were included. No significant difference was found in overall complications (OR 1.35, 95% CI 0.78-2.33, = 0.14) or early mortality (OR 1.01, 95% CI 0.42-2.43, = 0.97) between LPM and TVP groups. However, LPMs were associated with increased access site complications (OR 2.51, 95% CI 1.06-5.90, = 0.04), thrombotic events (OR 1.42, 95% CI 1.14-1.78, = 0.03), and respiratory complications (OR 1.43, 95% CI 1.01-2.03, = 0.05). Device-related complication rates were similar (OR, 1.09; 95% CI, 0.63-1.88; = 0.30). Heterogeneity was low across most outcomes. : Among patients with ESRD, leadless pacemakers did not reduce overall complications or short-term mortality compared to transvenous systems and were associated with increased risk of certain procedural complications. These findings could support a personalized approach to device selection in ESRD and highlight the need for further prospective studies to guide clinical decision-making in this population.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12383732 | PMC |
http://dx.doi.org/10.3390/biomedicines13081952 | DOI Listing |