The study aims to determine the uroflowmetry parameters of patients undergoing artificial urinary sphincter (AUS) implantation. Hence, uroflowmetry results pre- and post-AUS implantation and differences according to patient background were evaluated. Thirty-five patients who underwent primary AUS implantation for severe stress urinary incontinence due to radical prostatectomy were enrolled. All patients underwent uroflowmetry tests before and 1, 3, 6, and 12 months after AUS device activation. The patients reported outcomes using validated questionnaires: the King's Health Questionnaire (KHQ), the International Prostate Symptom Score (IPSS), and the quality of life (QOL) score. The mean patient age was 72.8 ± 5.4 years. The mean maximum flow rate ( ) value pre-AUS implantation (20.4 ± 11.3 mL/s) was significantly higher at 1-month post-AUS implantation and maintained at 12 months (26.0 ± 14.7 mL/s; =0.011). KHQ, IPSS, and QOL scores were significantly improved after AUS implantation. , and voiding volume was significantly higher in patients aged < 73 years compared to those aged ≥ 73 years. Uroflowmetry parameters were improved after AUS implantation and maintained for at least 12 months. Not only subjective outcomes but also objective outcomes of uroflowmetry parameters significantly improved after AUS implantation. This is the first report assessing uroflowmetry outcomes after AUS implantation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12377952 | PMC |
http://dx.doi.org/10.1155/aiu/9995075 | DOI Listing |
Adv Urol
August 2025
Department of Urology and Andrology, Kansai Medical University, Hirakata, Osaka, Japan.
The study aims to determine the uroflowmetry parameters of patients undergoing artificial urinary sphincter (AUS) implantation. Hence, uroflowmetry results pre- and post-AUS implantation and differences according to patient background were evaluated. Thirty-five patients who underwent primary AUS implantation for severe stress urinary incontinence due to radical prostatectomy were enrolled.
View Article and Find Full Text PDFInt Urol Nephrol
August 2025
Moscow Urology Center, Botkin Hospital, Moscow, Russia.
Introduction And Hypothesis: The aim of this study was to compare postoperative outcomes of same-day catheter-free discharge (SDS) and overnight observation (OBS) following artificial urinary sphincter (AUS) implantation.
Methods: A systematic literature search was performed in PubMed, Scopus, Cochrane Library, Google Scholar, and ClinicalTrials.gov up to April 2025.
Neurourol Urodyn
August 2025
Department of Urology, Keck School of Medicine of the University of Southern California, Los Angeles, California, USA.
Introduction: Many experience incontinence following prostate cancer treatment. Patients suffering from stress incontinence may benefit from an artificial urinary sphincter (AUS) or urethral sling, however, rates of these procedures following radical prostatectomy (RP) and radiotherapy (RT) are not well-defined. We aimed to assess rates of post-RP and post-RT utilization of AUS and urethral sling in a contemporary, national cohort from the large, federated database TriNetX.
View Article and Find Full Text PDFZ Orthop Unfall
July 2025
Zentrum für muskuloskeletale Chirurgie, Universitätsklinikum Essen, Essen, Germany.
The implantation of a tumour prosthesis for neoplastic indications can be considered to be a rare operation. After each tumour resection, the defect reconstruction plays a crucial role and always requires an individualised solution. In addition to modular tumour prostheses and growth prostheses for children, joint-preserving custom implants are being increasingly used.
View Article and Find Full Text PDFRSC Adv
July 2025
Department of Electrical Engineering, American University of Sharjah Sharjah United Arab Emirates.
Flexible and biocompatible electrodes are crucial components in developing future wearable and implantable biomedical devices. In this work, a novel composite bioelectrode from cellulose, supported by polydimethylsiloxane (PDMS), and glycerol were developed. Cellulose, an abundant and biodegradable biopolymer, provides the conductivity, while PDMS provides the support and the mechanical elasticity.
View Article and Find Full Text PDF