Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Wearable devices are becoming increasingly prevalent, offering the capability to estimate energy expenditure. Among these devices, the Apple Watch has demonstrated notable results in estimating energy expenditure during physical activity, especially compared to other wearable devices. Its accuracy in determining energy expenditure during electromyostimulation (EMS) training remains unexplored and is investigated in this work.35 young, healthy adults completed two stepwise increasing bike ergometer protocols (50/30/3 protocol) until the maximum physical load was reached with and without EMS support. Energy expenditure estimates from the Apple Watch Series 7 (Apple Inc., Cupertino, California, USA) were compared against gold-standard spirometric calorimetry measurements.The Apple Watch Series 7 underestimated energy expenditure compared to spirometric calorimetry for all data (mean difference: -27.4 kcal, LoA: 62.2 kcal), for ergometer exercise without EMS (mean difference: -28.8 kcal, LoA: 62.8 kcal), and for ergometer exercise with EMS (mean difference: -26.0 kcal, LoA: 62.4 kcal) data. We observed strong correlations between the Apple Watch Series 7 and spirometric calorimetry, with= 0.93 (< 0.001) for all data,= 0.93 (< 0.001) for exercise without EMS, and= 0.93 (< 0.001) for exercise with EMS.The Apple Watch Series 7 showed consistent accuracy in estimating energy expenditure during ergometer exercise, both with and without EMS. These findings suggest that the device can reliably monitor energy expenditure during EMS training, exhibiting similar accuracy limitations to conventional exercise settings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6579/adfcaf | DOI Listing |