Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
A novel approach is reported to quantify CuO NPs in aqueous samples by using digital image colorimetry (DIC), which is a rapid, low-cost, and facile method. We have used a colour recogniser application on a smartphone to register the gradual colour changes experimented, under λ = 365 nm radiation, by a dansyl-based chemosensor immobilised on cellulose paper, after interacting with aqueous dispersions of CuO NPs with concentrations between 5 and 100 µg L. The low limits of detection (LOD) and quantification (LOQ) (10.5 and 34.9 µg L, respectively) show a relevant sensitivity for this simple method, which also displays a good precision and accuracy (analytical recovery, 99 ± 1%). A comparison of the results similarly obtained for the modified paper through diffuse reflectance (DR) revealed worse detection parameters (LOD = 100.0 µg L and LOQ = 333.4 µg L). In addition, fluorescence spectroscopy (λ = 520 nm) demonstrated the ability of the free chemosensor (1.26 µg L in 20:80 (v/v) water-ethanol solutions) for the quantification of CuO NPs (LOD = 30 µg L and LOQ = 101 µg L), without improvement of the results obtained with DIC on the modified papers. The dissolved free chemosensor demonstrated selectivity towards CuO NPs in the presence both of metal ions common in aqueous samples as K, Na, Ca, Mg, Fe, or Al and of other usual nanomaterials as those of Cu, CdSe, TiO, and ZnO NPs.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12356722 | PMC |
http://dx.doi.org/10.1007/s00604-025-07439-9 | DOI Listing |