98%
921
2 minutes
20
A robust, all-solid-state potentiometric sensor was developed for the selective detection of dissolved ammonia (NH) in aqueous and gas-equilibrated environments. The sensor design is based on a coupled configuration of a nonactin-based ammonium-selective electrode (NH-ISE) and a hydrogen ion-selective electrode (H-ISE), enabling direct measurement of NH activity through the equilibrium: NH ⇌ NH + H. The resulting electrochemical cell exhibited a near-Nernstian response over a wide dynamic range, with a detection limit below 10 ppm and a response time under 6 seconds. In contrast to conventional membrane-based gas sensors, the dual-electrode system showed minimal signal drift and eliminated the need for gas-permeable membranes or internal filling solutions. Sensor performance was evaluated under various pH and ionic strength conditions, confirming matrix-independent behavior and suitability for direct application in complex environmental samples such as seawater and wastewater. The sensor also demonstrated excellent reversibility and real-time monitoring capability during dynamic NH fluctuation experiments in a freshwater aquaculture system, successfully tracking diurnal changes linked to photosynthetic and respiratory activity. A comparison with a commercial Severinghaus-type ammonia gas probe revealed significantly enhanced stability, faster response, and improved reproducibility for the proposed device. This dual-ion-selective electrode system offers a practical and high-performance platform for on-site NH detection in environmental, aquacultural, and biological monitoring applications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/d5an00647c | DOI Listing |
Analyst
September 2025
Chemistry Department, College of Science, King Khalid University, PO Box 9004, Abha, 62223, Saudi Arabia.
Correction for 'A dual-ion-selective electrode system for real-time monitoring of dissolved ammonia' by Ayman H. Kamel , , 2025, https://doi.org/10.
View Article and Find Full Text PDFAnalyst
September 2025
Department of Chemistry, Faculty of Science, Ain Shams University, Cairo 11566, Egypt.
A robust, all-solid-state potentiometric sensor was developed for the selective detection of dissolved ammonia (NH) in aqueous and gas-equilibrated environments. The sensor design is based on a coupled configuration of a nonactin-based ammonium-selective electrode (NH-ISE) and a hydrogen ion-selective electrode (H-ISE), enabling direct measurement of NH activity through the equilibrium: NH ⇌ NH + H. The resulting electrochemical cell exhibited a near-Nernstian response over a wide dynamic range, with a detection limit below 10 ppm and a response time under 6 seconds.
View Article and Find Full Text PDF