Article Abstract

Functional magnetic resonance imaging (fMRI) studies in cognitive and clinical neuroscience rely on blood oxygenation level-dependent (BOLD) contrast, measured with single-shot gradient-echo-planar imaging. However, conventional schemes encompass the acquisition of single-echo fMRI, which samples a single echo at a single-echo time (TE), facing limitations in disentangling neural signals from artifacts. Multi-echo (ME) fMRI captures images at multiple echo times within a single repetition time (TR) period and enables the separation of BOLD and non-BOLD signal components. Previous studies have highlighted the benefits of ME-fMRI but often relied on comparisons with suboptimal single-echo data derived from ME acquisitions, limiting the validity of these evaluations. This study performs a more rigorous comparison between three datasets: the data acquired with an optimized single-echo (OSE) fMRI sequence at the highest possible temporal resolution, those acquired with an ME-fMRI sequence, and, as previously reported in the literature, the echo-2 time-series extracted from the ME-fMRI data itself. ME-fMRI echo-2 comparison confirmed previous findings, which advantage the ME approach. However, the acquisition of multi-echo fMRI did not clearly outperform an optimized single-echo scheme. While OSE-fMRI exhibits benefits in terms of higher statistical power, ME-fMRI demonstrates superior performance at the single-subject level in terms of reliability (p < 0.05). Additional investigation and optimization could clarify the conditions under which one sequence may be preferred over the other.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12330833PMC
http://dx.doi.org/10.1162/IMAG.a.94DOI Listing

Publication Analysis

Top Keywords

multi-echo fmri
8
optimized single-echo
8
single-echo
6
fmri
5
me-fmri
5
multi-echo versus
4
versus single-echo
4
single-echo epi
4
epi sequences
4
sequences task-fmri
4

Similar Publications

Liver fat quantification at 0.55 T enabled by locally low-rank enforced deep learning reconstruction.

Magn Reson Med

August 2025

Medical Image and Data Analysis (MIDAS.lab), Department of Diagnostic and Interventional Radiology, University of Tuebingen, Tuebingen, Germany.

Purpose: The emergence of new medications for fatty liver conditions has increased the need for reliable and widely available assessment of MRI proton density fat fraction (MRI-PDFF). Whereas low-field MRI presents a promising solution, its utilization is challenging due to the low SNR. This work aims to enhance SNR and enable precise PDFF quantification at low-field MRI using a novel locally low-rank deep learning-based (LLR-DL) reconstruction.

View Article and Find Full Text PDF

Purpose: Lower extremity artery disease (LEAD), a major manifestation of peripheral arterial disease (PAD), is significantly influenced by vascular calcification, which impacts treatment outcomes. This study evaluates the feasibility of CT-like imaging using 3D multi-echo T2*-weighted image (T2*WI) for assessing vascular calcifications and vessel wall area in patients with LEAD.

Materials And Methods: A 3.

View Article and Find Full Text PDF

Background: Vertebral bone marrow (VBM) plays a critical role in bone homeostasis and metabolic health. Alterations in VBM fat and iron composition have been linked to age-related metabolic and musculoskeletal disorders, yet remain underexplored in large population-based studies.

Objectives: This study aimed to assess VBM adipose tissue and iron concentration in the UK Biobank imaging cohort ( = 26,524) using magnetic resonance imaging (MRI).

View Article and Find Full Text PDF

Three-dimensional reconstruction based on computed tomography/magnetic resonance imaging multimodal image fusion for parotid gland tumor diagnosis and treatment.

J Craniomaxillofac Surg

August 2025

Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, National Center for Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices& Beijing Key Laboratory of D

This research evaluated a novel computed tomography (CT)/magnetic resonance imaging (MRI) fusion-based three-dimensional (3D) reconstruction method for parotid gland tumor diagnosis and treatment. In 11 patients with primary parotid tumors adjacent to the facial nerve, contrast-enhanced CT and 3D multi-echo in steady acquisition MRI images were automatically fused, segmented, and reconstructed to visualize tumors and critical anatomical structures. Preoperative tumor localization and tumor-nerve relationship assessments matched intraoperative findings in 90.

View Article and Find Full Text PDF

Quantitative MRI (qMRI) enables objective, reproducible measurement of tissue-specific MR properties, offering improved diagnostic accuracy and deeper insight into disease mechanisms compared to conventional MRI. Parameters such as proton density (PD), relaxation rates (R1, R2), and myelin volume fraction (MVF) provide valuable information on tissue composition, water content, and myelination. Reference qMRI atlases based on these parameters are essential for identifying deviations in individuals and supporting clinical decision-making.

View Article and Find Full Text PDF