A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Robotic arm vs. stereotactic frame in deep brain stimulation surgery for movement disorders: a retrospective cohort study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Recently, robotic arms have been incorporated into the implantation of electrodes for deep brain stimulation (DBS).This study aimed to determine the accuracy of brain electrode placement, initial clinical efficacy, and safety profile of the robotic arm Neuromate (Renishaw) compared to a stereotactic frame in movement disorders.

Methods: This study involved two retrospective cohorts: one cohort was operated on using a stereotactic frame and the other with a robotic arm. This study was conducted at Barcelona Hospital Clinic.

Results: Seventy-seven patients were included, of whom 30 underwent surgery using the robot and 47 using a stereotactic frame. The postoperative improvement percentage of the Unified Parkinson's Disease Rating Scale at 3 months was similar in both groups (robot: 71.4 ± 18 vs. frame: 72.6% ± 17, P = 0.82). There were no significant differences in the perioperative complications (robot: 4% vs. frame: 4.3%, P = 0.93) or in the adverse reactions related to brain stimulation and medical treatment (robot: 18% vs. frame: 25%, P = 0.53). There was a slight improvement in the anatomical-radiological accuracy of brain electrode implantation assisted by the robotic arm, measured using radial error (robot: 1.01 ± 0.5 mm vs. frame: 1.32 ± 0.6 mm, P = 0.03).

Conclusions: Both systems (robotic and stereotactic frame) exhibited similar initial clinical efficacies and safety profiles. The use of the robotic arm Neuromate slightly improved the anatomical-radiological accuracy in the placement of DBS electrodes for movement disorders compared with the stereotactic frame.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12343702PMC
http://dx.doi.org/10.1007/s00701-025-06618-0DOI Listing