A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Development and Validation of a LC-MS/MS Method for Ripretinib and Its Metabolite: Example of a Journey From Laboratory Bench to Routine Application With a Greenness Assessment. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Therapeutic drug monitoring of protein kinase inhibitors is widely practiced worldwide. Based on the example of ripretinib dosage requested by a clinician, we detailed the process of method development, using a literature-based approach while ensuring the sustainability of the method to be as environmentally friendly as possible. Therefore, a UPLC-MS/MS method for ripretinib and its active metabolite was optimized and validated using the corresponding stable isotopic internal standards in human plasma. The procedure employed a mobile phase mixture of water with 1% acetic acid and 0.1% formic acid, and acetonitrile. Positive electrospray ionization was performed, coupling with multiple reaction monitoring of m/z 510.4 → 417.4 and 510.4 → 389.4 for ripretinib, and 496.3 → 403.3 and 496.3 → 375.3 for N-desmethyl-ripretinib. The method was successfully validated according to the current version of the ICH Guideline provided by the EMA. The greenness assessment score of this procedure was better than previously published approaches using the AGREE metric. The validated UPLC-MS/MS method successfully monitored ripretinib and its metabolite concentrations in clinical and preclinical models.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12340740PMC
http://dx.doi.org/10.1002/bmc.70190DOI Listing

Publication Analysis

Top Keywords

method ripretinib
8
ripretinib metabolite
8
greenness assessment
8
uplc-ms/ms method
8
method
6
ripretinib
5
development validation
4
validation lc-ms/ms
4
lc-ms/ms method
4
metabolite example
4

Similar Publications