A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Bicarbonate Buffer Dissolution Test Using the Floating Lid Method: Inter-Laboratory Reproducibility of pH Maintenance. | LitMetric

Bicarbonate Buffer Dissolution Test Using the Floating Lid Method: Inter-Laboratory Reproducibility of pH Maintenance.

Chem Pharm Bull (Tokyo)

Molecular Pharmaceutics Lab., College of Pharmaceutical Sciences, Ritsumeikan University, 1-1-1 Noji-higashi, Kusatsu, Shiga 525-8577, Japan.

Published: August 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Bicarbonate buffer (BCB) has been difficult to use in conventional dissolution tests because its pH rapidly increases as CO escapes from the air-water interface. Recently, the floating lid method was introduced as a convenient method for using BCB in dissolution tests. This study aimed to confirm the inter-laboratory reproducibility of pH maintenance of BCB using the floating lid method for both paddle and flow-through cell (FTC) methods. Three pharmaceutical companies and 1 academic research institute participated in this study. A BCB solution (pH 6.5, 15 mM) was employed as the test solution. In the paddle method, the pH values of BCB rapidly increased without the floating lid. The pH change (ΔpH) at 6 h ranged from +1.66 to +1.82 (50 rpm) and +1.96 to +2.02 (100 rpm). The floating lid effectively maintained the pH values in all laboratories, with ΔpH ranging from +0.13 to +0.17 (50 rpm) and +0.21 to +0.25 (100 rpm). The standard deviation of ΔpH was within 0.05 at both 50 and 100 rpm. Similarly, in the FTC method, without the floating lid, ΔpH ranged from +1.71 to +1.77 (reservoir), +1.59 to +1.72 (FTC), and +1.73 to +1.76 (sampling tube). With the floating lid, ΔpH ranged from +0.05 to +0.10 (reservoir), +0.05 to +0.09 (FTC), and +0.26 to +0.39 (sampling tube). The standard deviation of ΔpH was within 0.05. In conclusion, the inter-laboratory reproducibility of pH maintenance of BCB using the floating lid method was confirmed for both the paddle and FTC methods.

Download full-text PDF

Source
http://dx.doi.org/10.1248/cpb.c25-00283DOI Listing