A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Evaluation of Colistin Susceptibility in Carbapenem-Resistant Acinetobacter baumannii Isolates Using Broth Microdilution, MICRONAUT-MIC-Strip, and VITEK MS. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We aimed to analyze the colistin susceptibility using broth microdilution (BMD) and commercially available MICRONAUT-MIC-Strip (MMS) test and VITEK MS in carbapenem-resistant Acinetobacter baumannii (CRAB) isolates. Colistin susceptibility of 194 CRAB isolated from various clinical specimens between December 2020 and 2022 was determined by BMD and commercial MMS method. Minimum inhibitory concentrations of the commercial method were compared with the standard BMD. In the second part of the study, colistin susceptibility of the isolates was tested using the MALDIxin method, which detects modified lipid A, by VITEK MS, MALDI-TOF MS (bioMérieux, France). The presence of mcr-1-5 genes in resistant isolates was investigated using in-house multiplex polymerase chain reaction. Of these, 23 (11.8%) were found to be colistin resistant, whereas 171 (88.2%) isolates were susceptible. MMS categorical agreement was found to be 98.9% and essential agreement was 96.3%. The major error was found to be 1.03%, whereas a very major error was not detected. The MALDIxin test developed according to VITEK MS did not detect mutations responsible for lipopolysaccharide-induced colistin resistance in our isolates (expected peak at 1935-2033 m/z). The mcr-1-5 genes were not detected in our isolates. The MMS test is a reliable alternative method for the detection of colistin susceptibility in CRAB. Colistin resistance of the isolates used in our study was not associated with lipid A modification. Alternative mechanisms, such as efflux pumps, are a possibility. To our knowledge, this is the first VITEK MS-based method that enables rapid detection of colistin resistance in negative ion mode, and further studies are needed to determine colistin resistance in this way.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12332535PMC
http://dx.doi.org/10.1002/mbo3.70046DOI Listing

Publication Analysis

Top Keywords

colistin susceptibility
20
colistin resistance
16
colistin
9
carbapenem-resistant acinetobacter
8
acinetobacter baumannii
8
isolates
8
broth microdilution
8
mms test
8
mcr-1-5 genes
8
major error
8

Similar Publications