Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We report a comparison of modulation of intensity with zero effort (MIEZE), a neutron spin-echo technique, and neutron time-of-flight (ToF) spectroscopy, a conventional neutron scattering method. The evaluation of the respective recorded signals, which can be described by the intermediate scattering function (, τ) (MIEZE) and the dynamic structure factor (, ) (ToF), involves a Fourier transformation that requires detailed knowledge of the detector efficiency, instrumental resolution, signal background and range of validity of the spin-echo approximation. It is demonstrated that data obtained from pure water align well within the framework presented here, thereby extending the applicability of the MIEZE technique beyond the spin-echo approximation and emphasizing the complementarity of the two methods. Computational methods, such as molecular dynamics simulations, are highlighted as essential for enhancing the understanding of complex systems. Together, MIEZE and ToF provide a powerful framework for investigating dynamic processes across different time and energy domains, with particular attention required to ensure identical sample geometries for meaningful comparisons.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12321016PMC
http://dx.doi.org/10.1107/S1600576725003620DOI Listing

Publication Analysis

Top Keywords

mieze neutron
8
spin-echo approximation
8
mieze
5
comparison time-of-flight
4
time-of-flight mieze
4
neutron
4
neutron spectroscopy
4
spectroscopy report
4
report comparison
4
comparison modulation
4

Similar Publications

We report a comparison of modulation of intensity with zero effort (MIEZE), a neutron spin-echo technique, and neutron time-of-flight (ToF) spectroscopy, a conventional neutron scattering method. The evaluation of the respective recorded signals, which can be described by the intermediate scattering function (, τ) (MIEZE) and the dynamic structure factor (, ) (ToF), involves a Fourier transformation that requires detailed knowledge of the detector efficiency, instrumental resolution, signal background and range of validity of the spin-echo approximation. It is demonstrated that data obtained from pure water align well within the framework presented here, thereby extending the applicability of the MIEZE technique beyond the spin-echo approximation and emphasizing the complementarity of the two methods.

View Article and Find Full Text PDF

Scintillator-based Timepix3 detector for neutron spin-echo techniques using intensity modulation.

Rev Sci Instrum

March 2024

Neutron Technologies Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830, USA.

A scintillator-based Timepix3 (TPX3) detector was developed to resolve the high-frequency modulation of a neutron beam in both spatial and temporal domains, as required for neutron spin-echo experiments. In this system, light from a scintillator is manipulated with an optical lens and is intensified using an image intensifier, making it detectable with the TPX3 chip. Two different scintillators, namely, 6LiF:ZnS(Ag) and 6LiI:Eu, were investigated to achieve the high resolution needed for spin-echo modulated small-angle neutron scattering (SEMSANS) and modulation of intensity with zero effort (MIEZE).

View Article and Find Full Text PDF

A modulation of intensity with zero effort (MIEZE) setup is proposed for high-resolution neutron spectroscopy at momentum transfers up to 3 Å, energy transfers up to 20 meV and an energy resolution in the microelectronvolt range using both thermal and cold neutrons. MIEZE has two prominent advantages compared with classical neutron spin echo. The first is the possibility to investigate spin-depolarizing samples or samples in strong magnetic fields without loss of signal amplitude and intensity.

View Article and Find Full Text PDF

The small-angle neutron scattering data of nanostructured magnetic samples contain information regarding their chemical and magnetic properties. Often, the first step to access characteristic magnetic and structural length scales is a model-free investigation. However, due to measurement uncertainties and a restricted range, a direct Fourier transform usually fails and results in ambiguous distributions.

View Article and Find Full Text PDF

A method is reported to determine the phase and amplitude of sinusoidally modulated event rates, binned into four bins per oscillation, based on data generated at the resonant neutron spin-echo spectrometer RESEDA at FRM-II. The presented algorithm relies on a reconstruction of the unknown parameters. It omits a calculation-intensive fitting procedure and avoids contrast reduction due to averaging effects.

View Article and Find Full Text PDF