Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Fast and accurate determination of toxic and explosives compounds are necessary. Thus, a portable-electrochemical sensing system was developed for the rapid and sensitive detection of 2,4,6-trinitrotoluene (TNT) using a screen-printed electrode (SPE) modified with a CoO/MnO@MWCNTs nanocomposite. This nanocomposite combines the electrocatalytic activity of the hybrid metal oxides (CoO and MnO) with the high conductivity and surface area of multi-walled carbon nanotubes (MWCNTs), resulting in enhanced sensor performance. The modified SPE exhibited excellent electrocatalytic activity towards TNT voltammetric reduction, showing a well-defined voltammetric response. Electrochemical characterization using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) demonstrated the improved electron transfer kinetics and reduced charge transfer resistance at the modified electrode. Differential pulse voltammetry (DPV) was employed for quantitative TNT detection, achieving a linear response in the concentration range of 0.33 to 50 ppm with a detection limit of 0.153 ppm. The sensor demonstrated good selectivity against common interferents and other nitroaromatic compounds. Furthermore, the newly developed sensor surface exhibited satisfactory stability and reproducibility, making it a promising candidate for on-site and real-time TNT detection in environmental and security applications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12305795 | PMC |
http://dx.doi.org/10.1039/d5ra03807c | DOI Listing |