A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

High precision measurement of the light polarization plane rotation angle. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Sensors using tilted fiber Bragg gratings (TFBGs) are of great interest for researchers because of their high precision, compact size and resilience in harsh environments. However, the precision and reliability of the measurements made with them often depend on the polarization orientation. It is, therefore, necessary to control the rotation angle of the light polarization plane. Existing methods of measuring such an angle of light propagating in an optical fiber offer low measurement precision, require a long calibration process involving a human operator, or allow measurements only in narrow ranges of the rotation angle. In this study, we introduce a method of measuring the polarization plane rotation angle of light propagating in an optical fiber using two parallel TFBGs rotated relative to each other. The proposed method offers fully automatic calibration without human intervention and a greatly simplified calculation method. Our findings indicate that our method outperforms other methods in precision and reliability of measurement. The proposed method allows for measurements in the 0°-180° range with a mean absolute error of 0.064°.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.564677DOI Listing

Publication Analysis

Top Keywords

rotation angle
16
polarization plane
12
angle light
12
high precision
8
light polarization
8
plane rotation
8
precision reliability
8
light propagating
8
propagating optical
8
optical fiber
8

Similar Publications