Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In human medicine, the enthesis, or tendon-to-bone insertion, is generally considered a linked entity or 'enthesis organ' and plays a crucial biomechanical role. This study aimed to histologically assess the equine proximal third interosseus muscle (suspensory ligament) enthesis in 10 pelvic limbs from 7 horses. The area of the proximal third interosseus muscle enthesis was divided into 6 compartments based on post-mortem computed tomography and prepared for histology using haematoxylin/eosin and trichrome staining. The proximal third interosseus muscle enthesis showed a fibrocartilaginous nature. All adult entheses exhibited a characteristic four-layered structure consisting of ligament, uncalcified fibrocartilage, calcified fibrocartilage and bone. Juvenile specimens lacked clear layering, suggesting ongoing endochondral ossification. One or more smooth, regular tidemarks separated the uncalcified and calcified fibrocartilage, while the margins separating the ligament and bone from the fibrocartilage layer showed pronounced irregular interdigitations. Mean cellularity, fibrocartilage thickness and interdigitation size and shape varied among specimens. The fibrocartilaginous nature of the proximal third interosseus muscle enthesis in the equine pelvic limb supports the role of a stress dissipation mechanism and may have implications in the biomechanics and pathology of proximal third interosseus muscle enthesis injuries.

Download full-text PDF

Source
http://dx.doi.org/10.1111/ahe.70059DOI Listing

Publication Analysis

Top Keywords

proximal third
24
third interosseus
24
interosseus muscle
24
muscle enthesis
20
enthesis equine
8
equine pelvic
8
pelvic limb
8
fibrocartilaginous nature
8
calcified fibrocartilage
8
enthesis
7

Similar Publications

Bone mineral density assessment using radiofrequency echographic multispectrometry (REMS) in patients before and after total hip replacement.

Osteoporos Int

September 2025

Department of Rheumatology, First Faculty of Medicine, Charles University, Katerinska 32, Prague, 121 08, Czech Republic.

Unlabelled: REMS-BMD by radiofrequency echographic multispectrometry is primarily determined by a patient's BMI, age, and sex. Only about 2.8% of the changes in femoral neck REMS-BMD can be attributed to replacement of the total hip with metal implants.

View Article and Find Full Text PDF

Objective: To develop and validate a prognostic nomogram for predicting the risk of proximal ureteral impacted calculi, supporting personalized clinical management.

Methods: This retrospective, multicenter study employed a continuous cohort of 391 patients with proximal ureteral stones treated between January 2021 and April 2024. Data from Longyan People's Hospital (affiliated with Xiamen Medical College) comprised the training set, while independent external validation was performed using data from The Fifth Affiliated Hospital of Fujian University of Traditional Chinese Medicine.

View Article and Find Full Text PDF

Brazilin, a natural homoisoflavonoid, is the primary bioactive ingredient derived from the bark and heartwood of L. It has been proven to exhibit multiple biological activities and therapeutic potential in chronic degenerative diseases, fibrotic disorders, inflammatory diseases, and cancers. However, whether it is involved in regulating the pathological process of acute kidney injury (AKI) is not fully understood.

View Article and Find Full Text PDF

Purpose: The objective of the study was to evaluate the accuracy of femoral tunnel positioning in the reconstruction of the anteromedial (AM) bundle of the Anterior Cruciate Ligament (ACL) using the most proximal and posterior portion of the lateral femoral condyle cartilage (Point C).

Methods: From December 2022 to December 2023, 47 patients underwent anterior cruciate ligament reconstruction (ACLR) in outside in manner using Point C as an anatomical landmark for AM bundle ACLR. After the procedure, the patients underwent tomographic evaluation to assess the accuracy of the positioning, using Bernard's quadrants.

View Article and Find Full Text PDF

Background: The shape of the continuous wave Doppler (CWD) envelope in functional tricuspid valve regurgitation (fTR) results from the dynamic interplay between flow, pressure gradient and impedance. Although the v-wave cut-off shape in fTR is a well-recognized feature of severe TR, the complete spectrum of TR CWD shapes across the different fTR severity ranges has not been thoroughly explored, which is the scope of the present study.

Methods: In 245 patients with fTR, TR was graded with transthoracic echocardiography using the corrected proximal isovelocity surface area method and CWD shapes were scored, both qualitatively (using visual scoring into parabolic, triangular or v-wave cut-off categories) and quantitatively using a novel Vmax/Vmean parameter and time-to-peak velocity corrected for TR duration (TTP/TRD).

View Article and Find Full Text PDF