A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Comparison of Tissue Repair with Different Types of Microdissection Tips: A Randomized Histomorphometric Evaluation in Rats. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The aim of the study was to compare tissue repair of incisions made using different microdissection electrocautery tips in an in vivo animal model. Skin incisions were made, including the subcutaneous tissue, in 30 adult Wistar rats using four types of instruments: a scalpel blade number 15, knife-type electrocautery, microdissection needle, and thin-cut electrode. The animals were divided into five groups based on the euthanasia time-24 h, 48 h, 72 h, 7 days, and 14 days. Each animal received four incisions, one with each type of instrument. Histological and histomorphometric analyses were performed using hematoxylin and eosin (HE) and Picrosirius red stains. Analysis of variance (ANOVA) showed that the type of dissector had no significant effect on type I collagen levels ( = 0.615), whereas the euthanasia time had a significant influence ( < 0.001). Estimated marginal means for type I collagen showed minimal variation among groups, ranging from 35.4% to 36.5%, suggesting limited clinical differences between instruments. These results indicate that while the choice of dissector has a limited impact on type I collagen deposition, time is a determining factor in the wound healing process. The thin-cut electrode enables incisions with tissue repair comparable to that of a number 15 scalpel, as it performs cutting, coagulation, and blending functions at lower temperatures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12292716PMC
http://dx.doi.org/10.3390/bioengineering12070732DOI Listing

Publication Analysis

Top Keywords

tissue repair
12
type collagen
12
thin-cut electrode
8
type
5
comparison tissue
4
repair types
4
types microdissection
4
microdissection tips
4
tips randomized
4
randomized histomorphometric
4

Similar Publications