98%
921
2 minutes
20
This study evaluated diagnostic trends and the overall utility of cytology in feline patients through the analysis of a large, multicentric dataset from Portugal. A retrospective review of 3068 cytological cases from 130 veterinary practices was conducted, with samples categorised by anatomical location and lesion type. Diagnostic outcomes were statistically assessed, revealing an overall success rate of 66.20%. The highest diagnostic yields occurred in fluid samples (83.48%), glandular tissues (76.67%), and mucous membranes (75.81%), followed by organ-based samples (67.79%), miscellaneous tissues (66.98%), cutaneous/subcutaneous nodules (62.16%), and lymph nodes (57.93%). Neoplastic lesions showed age-associated prevalence, being more common in older cats, with epithelial and melanocytic lesions more frequent in females and round cell/mesenchymal lesions predominating in males. Non-diagnostic samples (33.80%) primarily resulted from insufficient cellularity or suboptimal quality, though no significant correlation existed between diagnostic success and clinical setting. This study underscores that cytology remains a fundamental diagnostic tool in feline medicine, particularly when combined with proper sampling techniques and complementary diagnostic methods, and reinforces its value in clinical decision-making, thereby supporting its broader utilisation in routine veterinary practice.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12298540 | PMC |
http://dx.doi.org/10.3390/vetsci12070671 | DOI Listing |
Vet Ophthalmol
September 2025
Ophthalmology Section, Equine Department, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.
Objective: To describe the use of transcorneal iris photocoagulation (TCIP) to improve intraocular visualization of intended incision lines, reduce hemorrhage, and facilitate excision of pigmented iridal tumors in four canine eyes and one feline eye.
Materials And Methods: A Rhodesian Ridgeback (treated bilaterally), a German Shepherd, a Labrador Retriever, and a Scottish Fold underwent sector iridectomy due to rapidly growing, pigmented, raised, iridal tumors affecting 1/4-1/3 of the iris circumference (3- to 4-clock hours). A diode laser was used to delineate the intended sector iridectomy incision lines, approximately 1-2 mm away from the grossly visible tumor margins, with the aim of improving visualization to achieve tumor-free margins and reduce tissue handling/trauma.
Vet Surg
September 2025
Department of Large Animal Medicine, College of Veterinary Medicine, University of Georgia, Athens, Georgia, USA.
Objective: To describe the long-term outcome of a horse that underwent a standing, ultrasound-guided, minimally invasive, biceps brachii tenotomy.
Study Design: Case report.
Animal: A 17-year-old Tennessee Walking Horse gelding.
Clin Pediatr (Phila)
September 2025
Department of Medicine (Infectious Disease), University of Connecticut Health Center, Boston University Medical Center, Falmouth Hospital, Falmouth, MA, USA.
A total of 101 patients with a clinical picture of persisting Lyme disease seen at the University of Connecticut Health Center and Boston Medical Center were recruited for the study to determine whether persistent infection is the likely cause. Brain SPECT imaging and responses to antibiotic treatments were recorded. Patients had more than 5 symptoms lasting more than 6 months.
View Article and Find Full Text PDFEmerg Med Australas
October 2025
Emergency and Trauma Centre, The Alfred Hospital, Melbourne, Victoria, Australia.
Objectives: Acute pyelonephritis (APN) is a common diagnosis among patients presenting to the Emergency Department (ED). It is treated by empiric antibiotics within the ED. With a rise in antimicrobial resistance globally, it is unknown whether patients are being managed with empiric antibiotics that are appropriate for the causative organisms of APN.
View Article and Find Full Text PDFMater Horiz
September 2025
TU Delft, Netherlands.
Soft wearable sensors offer promising potential for advanced diagnostics, therapeutics, and human-machine interfaces. Unlike conventional devices that are bulky and rigid, often compromising skin integrity, comfort, and user compliance, soft wearable sensors are flexible, conformable, and better suited to the dynamic skin surface. This improved mechanical integration enhances signal fidelity and device performance, while also enabling safer, more comfortable, and continuous physiological monitoring in real-world environments.
View Article and Find Full Text PDF