A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Evaluation of harmonization among thyroid hormone testing systems: A comparative study based on external quality assessment data. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: To evaluate thyroid hormone test harmonization using external quality assessment (EQA) data, guiding laboratory quality enhancement and big data interoperability.

Methods: EQA data for T3, T4, FT3, FT4, and TSH from January 2022 to December 2024 were collected. We calculated the total allowable error for both our laboratory (TEa-Lab) and peer groups (TEa-peer) using bias and coefficient of variation data. We derived harmonization indices (HI) by comparing TEa values against three biological variation thresholds (minimum, desirable, and optimal). An HI value ≤ 1 indicated satisfactory harmonization.

Results: The TSH test in our laboratory showed desirable harmonization; however, the HI for T3, T4, FT3, and FT4 ranged from 1.1 to 1.9, failing to reach the minimum harmonization level. Among the peer group tests, the level of coordination of each analysis system varies, and the harmonization levels ranging from below the minimum to the optimal harmonization level, even failing to reach the minimum level. The harmonization level of thyroid hormones between our laboratory and peer groups showed strong consistency.

Conclusion: The HI values quantitatively calculated from EQA data accurately reflect the harmonization level between thyroid hormone testing systems in the laboratory and peer groups. This helps identify laboratory issues and implement corrective actions, providing a reference for laboratory big data interoperability and clinical decision-making.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12284572PMC
http://dx.doi.org/10.1016/j.plabm.2025.e00491DOI Listing

Publication Analysis

Top Keywords

harmonization level
16
thyroid hormone
12
eqa data
12
peer groups
12
hormone testing
8
testing systems
8
external quality
8
quality assessment
8
harmonization
8
big data
8

Similar Publications