A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Lung ultrasound score and its correlation with modified Ross score in infants with left to right shunt. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: B lines in lung ultrasound are useful to diagnose heart failure in adults. This study was to done to correlate lung ultrasound score with heart failure severity in CHD.

Material And Methods: Fifty infants with left to right shunt underwent Ross scoring, measurement of NT pro BNP and lung ultrasound. Lung was divided into 14 zones (7 on each side); each zone was scored as: No B lines = 0, less than 3 B lines = 1, 3-7 B lines = 2, > 7 /or confluent B lines = 3. Total score was calculated by adding all scores. A modified ultrasound score was calculated by excluding scores of 1. Relationship between ultrasound scores and heart failure was assessed. Receiver operator curve (ROC) was generated to find a cut-off of ultrasound score to detect moderate or severe heart failure.

Results: No correlation was found between either total or modified lung ultrasound score with the modified Ross score or NT pro BNP. A cut-off of total lung ultrasound score of 11 gave an accuracy of 68% with area under the curve (AUC) of 0.64 to detect moderate or severe heart failure.

Conclusion: Utility of lung ultrasound in detecting severity of heart failure in infants with left to right shunts is limited at present due to its low accuracy and lack of standardised method of scoring.

Download full-text PDF

Source
http://dx.doi.org/10.1017/S1047951125001738DOI Listing

Publication Analysis

Top Keywords

lung ultrasound
28
ultrasound score
24
heart failure
16
infants left
12
score
9
ultrasound
9
lung
8
modified ross
8
ross score
8
left shunt
8

Similar Publications