A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Design, development, and evaluation of a novel shoulder phantom testbed for analyzing interaction forces and reachability of wearable exoskeletons. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The human need for rehabilitation, assistance, and augmentation has led to the development and use of wearable exoskeletons. Upper limb exoskeletons under research and development are tested on human volunteers to gauge performance and usability. Direct testing can often cause straining of the joints, especially the shoulder joint, which is the most important and flexible joint in the upper extremity of the human body. The misalignment of joint axes between the exoskeleton and the human body causes straining. To avoid this, we propose designing and developing a novel human shoulder phantom mimicking the shoulder complex motion and the humeral head translation that can help in the real-time testing of exoskeletons without the need for human volunteers. The device can be used to test the interaction forces and the maximum reachable position of the exoskeleton. It consists of three degrees of freedom (DOF) passive shoulder girdle mechanism and seven DOF glenohumeral joint mechanisms, of which six are passive revolute joints and one is an active prismatic joint mimicking the humeral head translation. All the passive joints are spring-loaded and are incorporated with joint angle sensors. A custom-made, three-axis force sensor measures the human-exoskeleton interaction forces. The design details, selection of joint springs, linear actuation mechanism, and the analysis of the phantom's reachable workspace are presented. The device is validated by comparing the interaction forces produced during the conventional exoskeleton-assisted and human-assisted phantom arm elevation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12277216PMC
http://dx.doi.org/10.1017/wtc.2025.10006DOI Listing

Publication Analysis

Top Keywords

interaction forces
16
shoulder phantom
8
wearable exoskeletons
8
exoskeletons human
8
human volunteers
8
human body
8
humeral head
8
head translation
8
joint
7
human
6

Similar Publications