A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Sport-specific performance assessment with oxygen uptake measurements in time trials and critical power tests. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This study investigated the added value of peak oxygen uptake ([Formula: see text]O) measurements during a 4-min time trial (4TT) or a 3-min all-out test (3MT) as compared to a ramp cycling test to enhance sport-specific performance assessment. Data from two cross-sectional studies were analysed. In study 1, 18 male and 13 female recreational cyclists performed two ramp tests and two 4TT on different days. In study 2, 23 male and 17 female CrossFit athletes performed one ramp test followed by a 3MT with an intervening 20-min recovery. The tolerance limits for ∆[Formula: see text]O between the two exercise tests was set to ± 0.13 L·min, reflecting common day-to-day variation in [Formula: see text]O. In study 1, comparing the first ramp test with the first 4TT and comparing the second ramp test with the second 4TT showed mean differences of 0.02 L·min (p = 0.930) and 0.03 L·min (p = 0.873), respectively. However, the tolerance limits were - 0.35-0.31 L·min and - 0.36-0.42 L·min, respectively. In study 2, the mean difference and tolerance limits were 0.08 L·min (p = 0.637) and - 0.42-0.58 L·min. Although the 4TT and 3MT show limited agreement with ramp tests for [Formula: see text]O, the lack of systematic deviations supports their value for sport-specific performance assessment.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12280066PMC
http://dx.doi.org/10.1038/s41598-025-09900-4DOI Listing

Publication Analysis

Top Keywords

sport-specific performance
12
performance assessment
12
[formula text]o
12
ramp test
12
tolerance limits
12
oxygen uptake
8
test 3mt
8
study male
8
male female
8
performed ramp
8

Similar Publications