A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Changes in inter observer variation of Schatzker and AO/OTA classification of tibial plateau fractures on addition of CT scan. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: Schatzker and AO/OTA classification are commonly used to classify tibial plateau fractures, but they are defined using plain radiographs and may not capture fully the complexity of these fractures. CT scan offers better visualization of occult fractures, joint depression and overall fracture morphology, but its impact on these classifications in term of interobserver variation is unclear. There is paucity of literature on this aspect, hence this study.

Methods: A total of 38 cases of tibial plateau fractures were classified by five different observers (four senior residents and one consultant) on the basis of Schatzker and AO/OTA classification. Initially, the observers classified the cases using plain radiographs and then reclassified the cases after supplementing the radiographs with CT scan images. The interobserver reliability was calculated using kappa coefficient.

Results: The interobserver agreement for Schatzker classification was found to be moderate on plain radiographs (mean κ = 0.593) and substantial after addition of CT scan images (mean κ = 0.630). The interobserver agreement for AO/OTA classification was found to be fair on plain radiographs as well as after addition of CT scan images (mean κ = 0.313 and mean κ = 0.320).

Conclusion: After providing advanced imaging both the classification systems showed improvement in the interobserver reliability. However, the change was found to be non-significant. This highlights the weakness of the plain radiograph based classification systems and indicates adoption of classifications based on advanced imaging.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12267129PMC
http://dx.doi.org/10.62347/YNVJ5137DOI Listing

Publication Analysis

Top Keywords

ao/ota classification
16
plain radiographs
16
schatzker ao/ota
12
tibial plateau
12
plateau fractures
12
addition scan
12
scan images
12
interobserver reliability
8
interobserver agreement
8
advanced imaging
8

Similar Publications